Data Sheet

dbl_li2gyw.pdfIssue23.11.2018 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
Small voltage cable
Li2GYw (SiHYw PV/P)
Conductor material: copper, bare
Conductor class: class 5 = fine stranded
Insulation: silicone rubber
Sheathing material: PVC
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Maximum permitted
conductor temperature:
180 °C
Permitted outer cable
temperature, fixed:
-40 - +90 °C
Permitted outer cable
temperature, in motion/
during installation:
5 - 90 °C
Bending radius, fixed
installation:
7,5 x DA
Nominal voltage U: 24 V
Core identification: red, blue
Application: As connecting cable between transformer and halogen lamps in low voltage lightning systems.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics Li2GYw (SiHYw PV/P)
p/n part name R
l.
[Ω/km]
R
bv.
[mm]
Cu
.
[kg/km]
G
.
[kg/km]
031847 HALOFLEX SiHYw PV/P
02X1,5 max. 24 V SW
13,3 27 28,8 44
031848 HALOFLEX SiHYw PV/P
02X2,5 max. 24 V SW
7,98 30 48 66
031849 HALOFLEX SiHYw PV/P
02X4 max. 24 V SW
4,95 31 76,8 96
Rl Conductor resistance
Rbv Bending radius, fixed installation
Cu Copper weight (GER)
G weight

Summary of content (1 pages)