Tus neeg siv phau ntawv

18
tely beforehand!
Possible reasons for the leaking repair could
be: Too much glue, glue was still liquid when
the pad was glued or pad too small.
ATTENTION!
Before you go into the water with the SUP
after the repair, check the repaired area for
sealing.
In case of major damage, you should never do
repairs yourself. Take the SUP to a specialist
workshop for repair!
Valve Check
To check whether the valve is leaking or de-
fective, proceed as follows:
1. Turn the valve cover counterclockwise
and remove it from the valve.
2. Make sure that there is no sand or other
foreign matter in the valve.
3. Inflate the SUP completely.
4. Close the valve.
5. Rinse the SUP around the valve with mild
soapy water. If bubbles form around the
valve, the valve must be tightened or re-
placed.
Tighten valve
ATTENTION!
From time to time it may be necessary to re-
tighten the valve so that no air can escape!
1. Turn the valve cover counterclockwise
and remove it from the valve.
2. Place the valve key on the valve until it
completely grips the valve.
3. Turn the valve key clockwise to tighten
the valve.
4. Close the valve with the valve cap and rin-
se the SUP around the valve with soapy
water. If there are no more bubbles, the
valve is tight.
Replace valve
If bubbles still form around the valve despite
tightening the valve, it must be replaced.
1. Let the air out of the SUP completely.
2. Turn the valve cover counterclockwise
and remove it from the valve.
3. Place the valve key on the valve until it
completely grips the valve.
4. Turn the valve key counterclockwise until
the valve can be unscrewed from the SUP.
5. Remove the defective valve from the SUP.
6. Insert a new valve into the SUP.
7. Place the valve key on the valve and turn
the valve clockwise to tighten it.
8. Place the valve cover on the valve and
turn it clockwise to tighten.
Note: You can obtain a replacement valve
from the service address given. For a better
sealing we recommend to use some silicone
grease or vaseline to lubricate the valve.
MAINTENACE
Check regularly that the pump is well lubrica-
ted before and during operation. To lubricate,
open the top cover and apply a thin layer of
grease to the seals and the pipe.
NOTES
Dispose of the SUP and packaging materials
according to current local regulations.
Dispose of the SUP and packaging in an en-
vironmentally friendly manner. The recycling