Datasheet
85°C
GM
24
Drawings for series GMA and GMB
D
h
+0,5
a
+0,5
L
±2
Fig1: GMA for ring clamp mounting
B
D
h
+0,5
a
+0,5
L
±2
Fig 2: GMB for stud mounting
Dimensions and mechanical data
dimensions, case with insulation sleeve
connecting terminals
mounting stud, GMB only
D
case length L available
in 5 mm
h
a
thread
max. torque
B
max. torque
[mm]
[mm]
[mm]
[mm]
[Nm]
[Nm]
35
40 … 120
6
13
M 5
2,0
M 8 x 12
4,0
40
40 … 120
5
18
M 5
2,0
M 8 x 12
4,0
50
40 … 120
5
22
M 5
2,0
M 12 x 16
10,0
65
40 … 180
5
28,5
M 5
2,0
M 12 x 16
10,0
75
40 … 230
5
31,7
M 5, M 6
2,0 ; 2,5
M 12 x 16
10,0
90
40 … 230
5
31,7
M 6
2,5
M 12 x 16
10,0
Accessories
GMA : connecting screws M 5 or M 6
GMB : connecting screws M 5 or M 6 + mounting nut M 8 or M 12
Remarks
Further mounting accessories like clamps, nylon cup nuts and insulation disks on request,
see “accessory equipment”
BACK TO INDEX
BACK TO START