Datasheet

105°C
AH
13
Series AH
Axial terminals
Low mounting height
High CV product
Long life 3000 h @ 105 °C
RoHS compliant
REACH compliant
Features
All contacts welded
High ripple current
Welded axial leads
High reliability
Applications
HiFi
Industrial
Telecommunications
Different case sizes, voltages and
capacitance combinations are
available on request.
Also in small lots.
General specifications
BACK TO INDEX
BACK TO START
Items
Characteristics
Rated capacitance range C
R
10 … 82.000 µF
Capacitance tolerance
20%
Rated voltage range U
R
16 … 450 V
Surge voltage U
S
U
R
≤ 315 V: U
S
= 1,15 U
R
U
R
> 315 V: U
S
= 1,10 U
R
Max. reverse voltage
2 V
Category temperature range
- 40°C ... + 105 °C
Leakage current I
L
after 5 min @ U
R
≤ 0,008 * C
R
[µF] * U
R
[V] + 6 µA [µA]
Useful life
3000 h @ 105 °C ; U
R
; I
R~
Requirements
Δ C/C ≤ 30 % of initial value
ESR ≤ 300 % of specified limit
I
L
≤ specified limit
Endurance test
2000 h @ 105 °C , U
R
Requirements
Δ C/C ≤ 20 % of initial value
ESR ≤ 130 % of specified limit
I
L
≤ specified limit
Climatic category IEC 60068
40/105/56
Voltage proof of the external insulation
D ≤ 25 mm: ≥ 1000 V AC
D > 25 mm: ≥ 2500 V AC
Sectional specification
IEC 60384-4
Ø leads
Up to 25 mm Ø : 0,8 mm ;
more than 25 mm Ø : 1,0 mm