Datasheet

MEK
103
MEK
RoHS compliant
REACH compliant
Features
With cap and connecting cable or plug
in tags
With clamp attachment or mounting
stud
Cable outcomming radial or axial
VDE approval for selected products
Applications
Motorstart
Whitegood motorcontrol
Different case sizes, voltages and
capacitance combinations
are available on request.
Also in small lots.
General specifications
Items
Characteristics
Clima category
10/060/21
Tolerance
10%
Specs. for selected items
VDE DIN EN 60252-2
Terminals
Cap and cable or faston tags 4,8 mm, 6,3 mm
single and double
The alternated current load may occur at most 20 times per hour with the following values:
Percentage duty cycle
AB 0,55 % ED
20 turn-ons with each 1,0 sec duration
AB 1,50 % ED
20 turn-ons with each 2,7 sec duration
AB 1,70 % ED
20 turn-ons with each 3,0 sec duration
BACK TO INDEX