Instructions / Assembly
(SEE ATTACHED DRAWING FOR PARTS LOCATION)
ASSEMBLY
CLEANING
1)  It is recommended to take precautionary measures and rinse down lid 
and reservoir prior to use.
2)  Securely install misters into top of manifold while being careful not to 
over tighten as this may cause threads to strip. 
3)  Attach manifold to water pump using the provided adaptor. Be careful 
to not over tighten this as well.
4)  Place water pump with manifold attached in center of reservoir.
5)  Insert water pump cord through molded outlet on side of the reservoir. 
Note: Use caution when using electricity and water!
6)  Fill reservoir until water level is 2 to 3 inches above the water pump. 
Note: Pump should be completely submerged at all times!
7)  For optimal results, adjust pH level to 6.0. A safe range for the pH level 
is between 5.8 and 6.5.
8)  For optimal results, the temperature of the water should remain 
between 70 and 85 degrees with the addition of EZ-CLONE
® 
Clear Rez
™
as a preventative measure. Apply Clear Rez
weekly at 1oz per five 
gallons. Using the system without Clear Rez is not recommended.
9)  Dip cutting in a rooting compound. EZ-CLONE Rooting Compound
™
is what we recommend. It should be applied directly to the cutting’s 
stem prior to placing the cutting in the system.
10)  Place cutting in the center of the circular cloning collar, making sure 
that at least 1 ½ to 2 inches of the cutting is suspended beneath the lid. 
All leaves should remain on the top of the lid.
11)  Insert the cloning collars, each filled with a cutting, into the lid. Make 
sure they are fitted securely to prevent leakage. 
12)  Set the lid onto the reservoir making sure that the lid is securely seated 
to prevent leakage.
13) EZ-CLONE
®
 systems work best with a florescent light. We recommend 
a dual T12 florescent light with 40watt bulbs placed 12 to 18 inches 
above the cuttings.
14)  Plug in light and water pump.
15) Finally, sit back and let the system make this your easiest cloning 
experience ever.
1)  Once cycle is complete remove all cuttings, pump/manifold assembly 
and cloning collars. Empty reservoir.
2)  Fill reservoir to the top with fresh water. Add bleach to the specified 
ratio.
3)  Remove red misters from manifold. Individually inspect the red misters 
and remove any debris that may be clogging them. Compressed air or a 
paper clip work well for this. Add misters to a cup of bleach water 
solution taken from your reservoir and allow to soak for 20 minutes.
4)  Place cloning collars in a five gallon bucket filled with fresh water and 
add one cup of bleach. Use another five gallon bucket with holes drilled 
in the bottom to help submerge the collars by placing it inside the filled 
bucket.
5)  Place pump/manifold assembly without misters back into the center of 
the reservoir. 
6)  Cycle pump and manifold completely submerged in bleach water 
solution for at least 20 minutes.
7)  While system is cycling the bleach water solution, flip the lid upside 
down and place in the reservoir so that is can soak in the bleach water 
solution.
8)  After cycling the bleach water solution for at least 20 minutes, empty 
the reservoir and do a quick wipe down with a scotch pad to ensure no 
build up is left. Remove drain plug assembly and wipe down with scotch 
pad.
9)  Re-install drain plug assembly and refill system with fresh water and 
cycle for 20 minutes to ensure no bleach is remaining in the system.
 10)  Empty reservoir and hand rinse the system.
 11) Rinse red misters thoroughly with fresh water and re-install into 
manifold.
 12)  Rinse and inspect each cloning collar thoroughly to ensure no bleach or 
plant matter remains.
 13)  Once everything is clean and sterilized, re-assemble the system and 
begin your next cycle. 
• Cleanliness is imperative. We strongly recommend
using Clear Rez.
• EZ-CLONE is designed specifically for the cloning process. 
It is not recommended for the adult stages of growth.
• Do not use distilled water in the EZ-CLONE. It may delay or 
prohibit root development.
• Room  or  water  temperature  must  be  controlled.  We 
recommend maintaining a water temperature between 70 
and 85 degrees. 
HELPFUL TIPS
Clear Rez
™ 
Dosage
16 unit - 3/4 cup of bleach 
32 unit - 1 cups of bleach
64 unit - 2 cups of bleach
128 unit - 4 cups of bleach
Bleach
Dosage
CONGRATULATIONS! on your purchase of the new and improved EZ-CLONE Plant Cloning System!
INSTRUCTIONS
IT IS VITAL THAT THE SYSTEM IS CLEANED REGULARLY 
AFTER EACH CLONING CYCLE. WE RECOMMEND 
RUNNING ONE TO FOUR CUPS OF BLEACH WATER 
THROUGH THE ENTIRE SYSTEM TO STERILIZE. 
For questions and replacement parts please contact us: www.EZCLONE.com | 916.626.3000 | 916.626.3001 | info@ezclone.com
16 unit - 3/4oz per week 
32 unit - 1oz per week 
64 unit - 2oz per week 
128 unit - 4oz per week 