Installation Guide

18
5.4 If a single platform is used as a landing at the top of the system with the ramp approach at 90
degrees to the door:
5.4.1 Place one guard corner post over the support tube (leg) extending out of the platform
corner pocket adjacent to the door and opposite ramp. Two of the corner post connector
brackets should be oriented toward the support tube where the guard will attach and the
other two away from the platform (FIG. 28). Do not tighten set screws.
Unused connector brackets should always be oriented away from the platform.
5.4.2 Place a guard over the support tube (leg) opposite the corner post connector brackets and
engage tabs on the guard into connector brackets on corner post (FIG. 28). Refer to detail
in Fig. 26 for engaging tab in connector bracket. Do not tighten set screws.
5.4.3 Place guard filler section over the other support leg on the ramp side with the connector
brackets oriented toward the platform (FIG. 29).
5.4.4 Place a guard over the remaining support tube (leg) and engage tabs on the guard into
connector brackets on guard filler section (FIG. 29).
FIG. 28