Instructions / Assembly

Table Of Contents
PATHWAY
®
3G Modular Access System Assembly Manual
Page 59 of 75
1
6.2. INSTALL RAMP HANDRAIL END LOOPS
6.2.1. The system may include end loops (FIG. 6.4). Upper and lower end loops are installed in
the same manner. If the end loop being installed doesn’t fit correctly (i.e., the
attachment plate is angled the wrong direction, the lower leg seems too long or short,
etc.), you are most likely trying to install it on the wrong end of the ramp or ramp run.
6.2.1.1. Install the o-ring over the swaged portion of the end loop until it rests against the
loop shoulder (FIG. 6.5).
6.2.1.2. Install one 1/4” x 1” long hex washer head self-drilling screw through the hole in
the end loop attachment plate into the ramp handrail post and tighten securely
(FIG. 6.6).
FIG. 6.4
FIG. 6.5
FIG. 6.6