Instructions / Assembly

1
PATHWAY
®
3G Modular Access System Assembly Manual Page 67 of 77
7.6. LIGHTNING GROUND ROD
Because aluminum can conduct electricity, the PLGRK (LIGHTNING GROUND ROD KIT) is available and
provides the components needed to ground a ramp system.
Prior to installing, ensure that any underground electrical conductors, natural gas lines,
water/drain lines, and or other interferences are located and will not hinder the installation.
7.6.1.
Drive the grounding rod straight into the ground as close as possible (within 1-1/2 feet
maximum) to one of the support tubes leaving approximately 2 exposed.
7.6.2.
Install the brace band around support tube. Place the #8 bare copper wire under the brace
band on the corner as shown (FIG. 7.9).
7.6.3.
Install the 5/16-18 carriage bolt, nut, and flat washer and tighten so that wire is in good
contact with the support tube.
7.6.4.
Install 5/8 grounding rod clamp to grounding rod. Place #8 wire between clamp and rod,
then tighten the clamp.
FIG. 7.9