eyeheight www.eyeheight.com GeNETics Product Information User Guide For: PM-2E/PM-4 Audio monitor Revision1-25 February 2002 Page 1 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg. No. 2855535 Telephone: +44 (0) 1923 256 000 Fax: +44 (0) 1923 256 100 email: eesales@eyeheight.
Table Of Contents The PM-2E/PM-4 Features and Overview ....................................................... 3 Applications for the PM-2E/PM-4 ..................................................................... 4 Associated Equipment for the PM-2E/PM-4 ..................................................... 4 Installation of the PM-2E/PM-4 Product ........................................................... 7 Installing the PM-2E/PM-4 into a Flexibox .......................................................
1 System Overview This manual describes the function of the PM-2E/PM-4. This unit monitors the embedded audio encoded within a SDI data stream. It also flags suitable alarms and displays the information onto a screen overlaid onto a video screen. Section 1 The PM-2E/PM-4 Product The PM-2E is a unit that will monitor the audio embedded in a SDI data stream and the PM-4 monitors the AES.
Figure 1 PM-2E/PM-4 Module. Section 2 Applications for the PM-2E/PM-4 Applications for the PM-2E/PM-4 include the following:- Automatic monitoring of a SDI channel and flagging suitable alarms to alert the operator in user defined situations. Figure 2 A typical PM-2E/PM-4 displays. Section 3 Associated Equipment for the PM-2E/PM-4 Hardware Requirements The PM-2E/PM-4 is a module and requires both a chassis and a control surface to function.
monitoring, and a master display in a 1RU Chassis then the recommended requirements would be: 4 off PM-2E/PM-4 Modules 1 off MD-2 Modules 1 off FB-9 Flexi-box 1 off FP-9 Flexipanel Software Requirements There are no special software requirements. The system is controlled via the front panel, however, it may be alternatively controlled by the Eyeheight front panel emulator, Softpanel which runs on a PC.
Figure 4 Minibox, Front and Rear. Page 6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg. No. 2855535 Telephone: +44 (0) 1923 256 000 Fax: +44 (0) 1923 256 100 email: eesales@eyeheight.
2 Installation Section 1 Installation of the PM-2E/PM-4 Product If this unit is already pre-installed in a Flexibox (FB-9) with either a local or remote panel from the Factory then refer to the "Hardware Installation Guide" which will be enclosed with the system.
CHP-100 SDI-TC-GPI Card Jumper Links on the Timecode and GPI I/O card Jumper J2 LK1 LK2 LK3 LK4 Function Set to the Right, SDI Jitter Filtering selection Set to Top, Polarity selection for GPI Relay Output#1 Set to Top, Polarity selection for GPI Relay Output#2 Set to Top, Polarity selection for GPI Relay Output#3 Set to Top, Polarity selection for GPI Relay Output#4 Diagram of a GPI Output (GPI1Æ4) Jumpers LK1Æ4, set the polarity of the relay Pin 1,3,5,7 Pin 2,4,6,8 Rear 25W D-Type connection (AUX) Pi
. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. closure. General Purpose Output #5 (GPO5). Open Collector Output (<100mA) General Purpose Output #6 (GPO6). Open Collector Output (<100mA) General Purpose Output #7 (GPO7). Open Collector Output (<100mA) General Purpose Output #8 (GPO8). Open Collector Output (<100mA) General Purpose Input #1 (GPI1). Pull to Ground to activate. ACCEPT ALARM. General Purpose Input #2 (GPI2). Pull to Ground to activate. General Purpose Input #3 (GPI3).
3 Operation Section 1 Control of the PM-2E/PM-4 Control of the PM-2E/PM-4 is generally done using an FP-9 Flexi panel. It is also possible to control this unit with an FP-10 Panel (Desktop Panel) or if the unit is mounted in a Mini-Box limited control will be available with the mini-box Preset select buttons which will have been pre-set at the factory. The unit can also be controlled remotely using a PC running the Softpanel software.
Menus 04-07 Audio Bars =On Menu Num. 4 Top Level Menus Audio Scale =On Heading Audio Bars 5 Audio Scale 6 Ovrlay level Automation Off,On Default is On Off,On Default is On 0-100% Default is 100 7 Menu Num. 8 Pressing this will draw or clear the audio scales. The fade level of the audio bars and audio scales.
Menus 20-23 Ident H posn =15 Menu Num. 20 Top Level Menus Ident V posn =65 Heading Ident H posn 21 Ident V posn 22 Text H size Text V size 23 Automation 0-999 Default is 15 0-999 Default is 65 0-2, Default is 1 0-1, Default is 0 Text H size =1 Text V size =0 Function This sets the horizontal position of the Ident bar on the video image. This sets the vertical position of the of the Ident bar on the video image. This sets the horizontal size of the text. This sets the vertical size of the text.
4 Technical Appendix Technical Specification for the PM-2E/PM-4 Number of Inputs Type of Inputs Line Length Number of Outputs Type Of Outputs Total Number Of BNC Connections SDI Output Jitter 1 270Mbit Serial Digital Video Inputs 75 Ohm At least 200 Meters of PSF1/3 (Typically 275 Meters) 3 Output BNC’s per Card (Configurable). 270Mbit Serial Digital Video Outputs, 75 Ohm, 800mV 5, consisting of 1 Fixed Input and 3 Jumper Configurable outputs. (One BNC not used) The system will add less than 0.