User guide

The maximum peak-to-peak Amplitude is limited by the free capacity of the chosen
delay line.
The maximum Frequency of the periodic jitter source depends on the chosen
waveform. Refer to the technical specifications.
You can switch between sine, rectangular, or triangular jitter source waveforms.
Periodic Jitter 2 – Constant Amplitude Sweep Parameters
The Periodic Jitter 2 – Constant Amplitude Sweep is characterized by:
Amplitude
Frequency Range
Waveform
Sweep Time
Nr. of Steps
A graph indicates whether the chosen setting of frequency and amplitude is
tolerable.
Jitter Tolerance Tests 8
Agilent J-BERT N4903B High-Performance Serial BERT 423
Amplitude
Frequency
Waveform