User guide
Interval Results
•
Error Free Seconds
The number of seconds in which no errors were measured is displayed here.
•
Error Free Deciseconds
The number of deciseconds in which no errors were measured is displayed
here.
•
Error Free Centiseconds
The number of centiseconds in which no errors were measured is displayed
here.
•
Error Free Milliseconds
The number of milliseconds in which no errors were measured is displayed
here.
•
Errored Seconds
The number of seconds in which errors were measured is displayed here.
•
Errored Deciseconds
The number of deciseconds in which errors were measured is displayed here.
•
Errored Centiseconds
The number of centiseconds in which errors were measured is displayed here.
•
Errored Milliseconds
The number of milliseconds in which errors were measured is displayed here.
•
Sync Loss Seconds
The number of seconds in which the error ratio was greater than the sync
threshold is displayed here.
Accumulation Parameters
•
Elapsed Time
The time elapsed during the accumulation period is displayed here.
•
Percent Complete
For single and repeat accumulation modes, the percentage of the accumulation
period completed is displayed here to one decimal place. For repeat mode, this
percentage is recalculated each time the accumulation period repeats.
•
Accumulation Mode
The type of accumulation mode is displayed here. The mode can be Manual,
Single, or Repeat.
7 Evaluating Results
382 Agilent J-BERT N4903B High-Performance Serial BERT