User guide

:MTES:INP:MODE DIFF
In the above example, the Y1 and Y2 values define the mask with an absolute
voltage value. In some mask files, Y1 and Y2 values are not specified, and so the
voltage value is relative to either Vtop and Vbase, or to the eye boundaries specified
by the user in the GUI.
A mask can be set in two modes, either differential, or single. The above example,
":MTES:INP:MODE DIFF", sets the mode of the mask file to differential. The mask
mode, when defined, should match the mode set in 'ED Input Setup Dialog'. In case
it doesn't match, an error message will indicate this mismatch.
How to Enter Notes?
There is a tab on the top left corner of the graph for entering notes.
To enter notes:
1
Click on the Note Tab.
2
Enter your notes in the drop down text box. This gives the timestamps of the
comments entered. It’s a scrollable editor where your latest comments are
entered at the end.
How to Save and Recall
To Save the following measurements:
Eye Diagram
Advanced Analysis 6
Agilent J-BERT N4903B High-Performance Serial BERT 329