User guide
N O T E
The BER Threshold will usually be 0, since you want the measurement to fail if a
single bit was received in error.
The pass/fail threshold applies to all measurement points. An
icon indicates all measurements where the bit error rate is higher than this
threshold, as shown in the figure below:
View Tab
The following parameters can be set on the View tab of the Properties dialog box:
You can analyze for:
•
All Errors
To display all errors.
•
Errors if 0s Expected
To display the errors if "0" is expected, but "1" received.
•
Errors if 1s Expected
To display the errors if "1" is expected, but "0" received.
You can set the Timing Unit for the display of the relative time of the measurement
points on the Parameters tab. Choose between Unit Interval and Seconds to select
the unit.
6 Advanced Analysis
314 Agilent J-BERT N4903B High-Performance Serial BERT
Analyze
Grid