Error Ratio - Reference
8B/10B Presets Dialog
The 8B/10B Presets dialog allows you to enter a short description, values for Filler
Primitives definition and Alignment Symbol for the new preset. This dialog contains
the following elements:
Filler Primitives Definition
Filler Primitives are inserted or deleted for clock tolerance compensation. These
are not compared and therefore cannot be counted as errors. Filler Primitives
contain filler symbols. A maximum of 4 alternative filler primitives can be used.
Each filler primitive can consist of upto 4 filler symbols. Filler symbols are separated
by a comma (,).
Example: For SAS we have 4 filler primitives each consisting of 4 filler symbols.
K28.5,D10.2,D10.2,D27.3
K28.5,D7.0,D7.0,D7.0
K28.5,D1.3,D1.3,D1.3
K28.5,D27.3,D27.3,D27.3
The following are the supported standards along with their filler symbols: