User guide

Table 14
Icon Name Description
From PG Click this icon to upload
the present sequence from
the pattern generator to
the Sequence Editor. This
allows you to inspect and
edit a sequence that has
been loaded with a
program.
Properties Click this icon to change
the properties of the
current sequence. See
“Setting Sequence
Properties” on page 107
for details.
Break Click this icon to terminate
an infinite loop that is set
to "manual" break
condition. Sequence
execution continues with
the next block.
Reset Click this icon to interrupt
and re-initialize a running
sequence.
If the sequence start
condition is IMMediate,
the sequence restarts
immediately.
If the sequence start
condition is a signal at the
Aux In port, the sequence
restarts upon the specified
signal.
If the sequence start
condition is "Command",
sequence execution starts
when the Start button is
clicked.