Installation guide

ScriptWorks® Technical Note – Hqn028 – HQMulDev for 4.1 Page 12 Revision 1.4, 96.09.24
The PelBox interface has an extra jumper (LK5) which must be linked in order to access the
resolution and exposure selection features of the PelBox 3000 and VR series. It is not required
for the 108 etc. where resolution and exposure cannot be set by the RIP.
When driving a Linotype image setter you should set the LI5 dressing (if LI5 is being used) on
the setter itself to 8 data bits, 1 stop bit, 9600 baud, no parity. The LI2 dressing should specify
sender master, receiver clock, asynchronous mode. Please follow the directions in the manual
supplied with the image setter itself to set these dressings.
When driving an UltreSetter or ExxtraSetter you may need to adjust a rotary hex switch on
the top edge of the interface card. For card version 190-32 and later, with PROM version 7.0
and later, the hex switch should be set as follows. The switch should be left at ‘1’ on earlier
cards.
1 UltreSetter –P, –E and Vision (Mark 10, 20 and 30, 72 and 94 pica (EX) models)
2 UltreSetter 3000 and 4000 (Mark 40 and 40 EX)
3 ExxtraSetter Exxpress 300 (also sold as the DeskSetter Express).
4 ExxtraSetter 300 (also sold as the DeskSetter)
Except where noted above for the Ultre card the rotary hex switch on the top edge of these cards
should be left at ‘1’.
In cases where you experience difficulties in output it is possible to request the card to generate
test patterns, using positions 9 (checkerboard output), A (close horizontal lines), B (widely
separated horizontal lines) and C (vertical lines). More information on these options is available
direct from HighWater Ltd.