User’s Manual YCS 100 www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664 Kyodo Building 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 Fax +81.3.3511.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有 露的危险电压,有触电危险。 注意 阅读说明书 • 用户使用该设备前必须阅读并理解所有 安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使用。 遵守警告 • 用户应遵守产品和用户指南上的所有安全 和操作说明。 避免追加 • 不要使用该产品厂商没有推荐的工具或追 加设备,以避免危险。 警告 电源 • 该设备只能使用产品上标明的电源。 设备必须 使用有地线的供电系统供电。 第三条线(地线)是 安全设施,不能不用或跳过 。 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设 备后或桌面电源的电源线,或任何接到市电系统的 电源线。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 维护 • 所有维修必须由认证的维修人员进行。 设备内 部没有用户可以更换的零件。为避免出现触电危险 不要自己试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来 防止机内敏感元件过热。 不要用任何东西挡住通 风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。必须使用 与厂家推荐的相
Table of Contents Chapter One • Introduction ................................................... 1-1 About this Manual .................................................................... 1-2 About the YCS 100 .................................................................... 1-2 Features ........................................................................................ 1-2 Application Diagram.................................................................
Table of Contents, cont’d YCS 100 1 Chapter One Introduction About this Manual About the YCS 100 Features Application Diagram ii YCS 100 • Table of Contents
Introduction About this Manual This manual contains information about the Extron YCS 100 Transcoder, and discusses how to install, configure, and operate it. The terms “YCS 100,” “YCS,” and “transcoder” are used interchangeably throughout this manual. About the YCS 100 The Extron YCS 100 Transcoder has a composite video to S-video (luminance [Y] and chrominance [C]) decoder and an S-video to composite video encoder in one product.
Introduction, cont’d YCS 100 2 Chapter Two Installation and Operation Installation Overview Mounting the YCS 100 Rear Panel Wiring the Power Connector Front Panel Operation Troubleshooting 1-4 YCS 100 • Introduction
Installation and Operation Installation Overview To install and set up the YCS 100, follow these steps: 1 Mount the YCS 100 on a rack shelf, furniture, or projector bracket if desired. 2 Connect your input and output devices to the YCS 100’s rear panel connectors. 3 Wire the provided 2-pin captive screw connector to the external power supply. (See Wiring the Power Connector, later in this chapter.) 4 Apply power to the YCS 100 and to the input and output devices. 3.
Installation and Operation, cont’d 6" Deep Rack Shelf 1/2 Rack Width Front False Faceplate Front false faceplate uses 2 screws. (2) 4-40 x 3/16" Screws Use 2 mounting holes on opposite corners. Figure 2-3 — Mounting a YCS on a 6-inch rack shelf Figure 2-4 — Attaching the back of rack mounting brackets to the YCS 100 5. Mount the unit to the rack support, using the two included rack screws (see figure 2-5, below).
Installation and Operation, cont’d Furniture mounting To furniture-mount the YCS 100, use the optional MBU 123 VersaTools under-desk mounting kit (part #70-212-01), as follows. 1. If rubber feet were previously attached to the bottom of the unit, remove them. 2. Remove the two screws from one side of the YCS. Retain the screws for possible later reassembly. 3. Attach one bracket to the side of the unit, using the provided machine screws (see figure 2-6, below).
Installation and Operation, cont’d Using the PMK 300 Projector Mount Kit The PMK 300 Multi-Product Projector Mount Kit (#70-374-01) mounts up to three quarter-rack width products to a projector ceiling mount pole. The YCS 100 can be mounted above the display device with the front panel facing either down or up. The quarter rack width plate can also be used to mount the YCS external desktop power supply. Follow these steps to projector-mount the YCS 100 using the PMK 300: 1.
Installation and Operation, cont’d 3. Affix the supplied rubber pad to the side of the U-bolt clamping plate that the projector pole contacts. 4. Place the U-bolt around the ceiling pole and insert the two legs of the U-bolt through the slotted holes on the bracket’s mounting plate, then through the round holes on the backing brace. Extron YCS 100 Rear Plate Transcoder Contoured Base • For a typical (1.5" to 2.
Installation and Operation, cont’d Secure the L-shaped bracket to the square U-bolt using the included hex nuts, washers, and lock washers. Tighten the hex nuts securely. 10. Be sure to tighten the hex nuts securely enough that the PMK 350 does not slide down the ceiling pole. A socket wrench is recommended to tighten the hex nuts. N Power connector — Plug the external 12 VDC power supply into this 2-pin, 3.5 mm captive screw connector.
Installation and Operation, cont’d N Your YCS may have been shipped with a blue captive screw connector. This blue connector can be plugged into either a blue or an orange power receptacle. The blue connector does not have the extended tail or the included tie-wrap. C Do not tin the stripped power supply leads before attaching the captive screw plug to them. Tinned wires are not as secure in the captive screw connectors and can be easily pulled out. They may also break after being bent several times.
Installation and Operation, cont’d YCS 100 A Appendix A Figure 2-15 — Jumper on YCS 100 internal board N 4. When the YCS is delivered from the factory, a shunt is attached to one prong of the jumper. This shunt is used to enable the jumper in step 4. Enable (close) the CR8 jumper by placing the shunt on both prongs, as shown below. Specifications, Part Numbers, and Accessories Specifications Included Parts Accessories Open Closed Figure 2-16 — Enabling the CR8 jumper 2-16 5.
Specifications, Part Numbers, and Accessories Specifications N The YCS 100 includes a built-in S-video decoder and a composite video encoder. The encoder portion and the decoder portion are independent and may be used simultaneously. Video — encoder portion Gain ................................................ Unity Standards ........................................ NTSC 3.58, NTSC 4.
Specifications, Part Numbers, Accessories, cont’d Rack mount .................................... Yes, with optional 1U rack shelf, part #60-190-01 or 60-604-01; 1U, 6” deep rack shelf, part #60-190-10 or 60-604-10; or VersaTools® rack shelf, part #60-190-20 or 60-604-20. Above-projector mountable with the optional PMK 100 Mini Projector Mount Kit (#70-217-01), the PMK 300 MultiProduct Projector Mount Kit (#70-374-01), or the PMK 350 Low Profile Projector Mount Kit (#70-563-03). Enclosure type .............
Specifications, Part Numbers, Accessories, cont’d A-6 YCS 100 • Specifications, Part Numbers, and Accessories