User guide

XTP T VGA Transmitter • XTP System Configuration Software 26
EDID Minder
Use the EDID Minder screen to assign unique EDID to the input or match current output
resolutions to the input. Click the EDID Minder icon (see figure 27,
1
) on the global
navigation bar. The EDID Minder screen opens.
The EDID Minder screen displays a table of EDID options and connected output devices,
which are each represented by output display icons.
Factory default EDID options are displayed in blue.
Connected output resolutions and devices are displayed in green.
Custom loaded or saved EDID options are displayed in yellow.
Figure 27. EDID Minder Screen
Assign EDID
1. Select an available EDID setting (represented by a blue, green, or yellow output display
icon) from the Favorites, Connected Outputs, or Available EDID panel (see
2
-
4
).
2. In the list of inputs on the right side of the screen, select the check box of the
connected input (see
5
).
TIP: Alternatively, click the Assign to All button (see figure 27,
7
) to assign a
selected EDID to the input.
3. Click the Assign button (see
6
) below the input area.
TIP: Alternatively, EDID can be assigned by dragging and dropping the desired EDID
onto the input.
Import EDID
1. On the EDID Minder screen, click the Add EDID to Library button (see
8
). A
Windows Explorer window opens.
2. Select the desired EDID file and click Open. The EDID appears in the Available EDID
panel (see
4
).
3. Assign the EDID from the Available EDID panel to import the EDID setting to the device.