User guide

XTP T FB 202 Floor Box Transmitter • Installation 4
Installation
This section contains information for installing, connecting, and wiring the XTP T FB 202.
Topics in this section include:
Installation Overview
Adapter Plates
Side Panel Connectors
Top Panel Features
Mounting
Connection and Wiring Details
Installation Overview
Install the XTP T FB 202 into an Ackermann GB3 (OBO Bettermann), MK Electric CableLink
Plus Modular, MK Electric CableLink Plus Single Pan, Electraplan, or PUK floor box.
CAUTION: Risk of personal injury. Failure to check the items listed below may result
in personal injury.
ATTENTION: Failure to check the items listed below may result in property damage.
1. Check that the installation of the floor box meets government, building, electrical, and
safety codes.
2. Install the floor box according to the instructions of the manufacturer.
3. Prepare and pull the cables through the floor box.
TIP: Secure cables with clamps or ties to provide strain relief.
4. Trim back and insulate shields with heat shrink.
ATTENTION: To prevent short circuits, the outer foil shield can be cut back to the
point where the cable exits the cable clamp. Both braided and foil shields should
be connected to an equipment ground at the other end of the cable.
5. Install the appropriate adapters to the desired position in the floor box (see Adapter
Plates on page 5).
6. Connect cables to the side panel connectors located below the adapter plates (see
Connectors Below the Adapter Plates on page 7).
7. Mount the XTP T FB 202 to the floor box (see Mounting on page 10).
8. Connect appropriate devices to the remaining side (see Connectors Above the
Adapter Plates on page 8) and top (see Top Panel Features on page 9) panel
connectors.
9. Configure the XTP T FB 202 with SIS commands (see SIS Configuration and
Control on page 18) or the XTP System Configuration Software (see XTP System
Configuration Software on page 23).