Setup guide
36 XTP CrossPoint 1600 and 3200 • Remote Control 37XTP CrossPoint 1600 and 3200 • Remote Control
NOTE: 
X@
 = Output number  01 – 16 or 32 
X1)
 = Mute  0 = off (unmuted)  1 = on (muted) 
X2%
 = Video and audio mute  0 = no mute  1 = video mute  2 = audio mute  3 = video and audio mute
Command SIS Command 
(Host to Unit to Endpoint)
Response 
(Endpoint to Unit to Host)
Additional Description
Audio mutes
Audio mute, HDMI and S/PDIF
X@
*1Z Amt
X@
*1
]
Mute output 
X@
 embedded digital (audio off).
Audio mute, analog
X@
*2Z Amt
X@
*2
]
Mute output 
X@
 analog (analog audio off).
Audio mute, both
X@
*3Z Amt
X@
*3
]
Mute all output 
X@
 audio (digital and analog audio off).
Audio unmute
X@
*0Z Amt
X@
*0
]
Unmute output 
X@
 (digital and analog audio on).
Read audio mute
X@
Z
X1)]
1 = mute on, 0 = mute off.
Global audio mute, HDMI and 
S/PDIF
1*Z
Amt1
]
Mute all embedded digital audio outputs.
Global audio mute, analog
2*Z
Amt2
]
Mute all analog audio outputs.
Global audio mute, both
3*Z
Amt3
]
Mute all embedded digital and analog audio outputs.
Global audio unmute
0*Z
Amt0
]
Unmute all audio outputs.
View video and audio mutes
View output mutes
E
VM
}
X2%
1
X2%
2
... 
X2%
n
]
Each 
X2%
 response is the mute status of an output, 
starting from output 1. n = either 16 or 32.
Example : 
(XTP CrossPoint 3200)
E
VM
}
Audio is muted on outputs 2 and 3, video on 
output 5, and video and audio on output 26. All 
other outputs are unmuted.
Mut02201000000000000000000003000000
]
Command SIS Command 
(Host to Unit to Endpoint)
Response 
(Endpoint to Unit to Host)
Additional Description
Relay controls
Turn on an endpoint relay
EX@
*
X2^
*1RELY
}
Rely
X@
*
X2^
*1
]
Turn on relay 
X2^
 in output 
X@
.
Turn off an endpoint relay
EX@
*
X2^
*0RELY
}
Rely
X@
*
X2^
*0
]
Turn off relay 
X2^
 in output 
X@
.
Toggle an endpoint relay
EX@
*
X2^
*2RELY
}
Rely
X@
*
X2^
*2
]
Toggle (on-to-off or off-to-on) relay 
X2^
 in output 
X@
.
Pulse an endpoint relay
EX@
*
X2^
*3*
X2&
RELY
}
Rely
X@
*
X2^
*3*
X2&]
Turn on relay 
X2^
 in output 
X@
 for an interval dened 
as 
X2&
. Each step of 
X2&
 is 16 ms.
Example:
E
1*2*3*45RELY
}
Rely1*2*3*45
]
Turn on relay 2 in output endpoint 1 for 720 ms 
(0.72 sec, 
X2&
 = 45 * 16 ms = 720 ms).
View an endpoint relay status
EX@
*
X2^
RELY
} X2*]
On or off.
NOTE: 
X!
 = Input number  01 – 16 or 32 
X2^
 = Relay on endpoint  1 or 2 
X2&
 = Pulse duration  0 through 65535 (each step = 16 ms, see the example above) 
X2*
 = Relay status  0 = Off  1 = On