6. Thread the power wires through the length of the electrical conduit tube.
7. Install the EMT adapter plate with conduit attached into the opening from which the IEC
connector was removed in step 5 .
LINE
NEUTRAL
L
N
Conduit Nut
EMT Adapter Plate
Te rminal Block
Zip-Tie
Ground
Wire Nut
Hot
Te rminal (Black)
Neutral
Te rminal (White)
8. Slide the conduit nut over the bundle of wires exiting the conduit and onto the conduit
itself. Hand tighten the conduit nut to the conduit.
9. Attach the EMT adapter plate assembly to the XPA using the 2 screws removed in
step 5.
10. Connect the black hot (line) and white neutral wires to the terminal block using the
2 screws that were removed in step 3. Use the included zip tie to secure the two wires
together close to the terminals. See the following illustration.
WARNING: Ensure that you observe correct wire polarity. The following illustration
shows the location of the hot (L) and neutral (N) terminals.
LINE
NEUTRAL
L
N
Conduit Nut
EMT Adapter Plate
Te rminal Block
Zip-Tie
Ground
Wire Nut
Hot
Te rminal (Black)
Neutral
Te rminal (White)
11. Connect the ground wire, as shown above, to the grounding stud on the bottom of the
enclosure using the nut removed in step 4.
12. Replace the cover of the XPA by attaching the 8 screws removed in step 2.