User guide

Thermal dissipation
Standby ................................... <1 watt (3 BTU/hr)
Idle
XPA 1002 ........................... 10 watts (34 BTU/hr)
XPA 2001-70V, XPA 2001-100V
12 watts (41 BTU/hr)
1/8 power (pink noise)
XPA 1002 ........................... 4 ohms (x2): 18 watts (62 BTU/hr)
8 ohms (x2): 15 watts (53 BTU/hr)
XPA 2001-70V ................... 70 V (x1): 21 watts (71 BTU/hr)
XPA 2001-100V ................. 100 V (x1): 20 watts (69 BTU/hr)
Protection ...................................... Clip limiting, thermal, short circuit, DC output
Indication ....................................... Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, short
circuit, or DC output protection
Mounting
Rack mount ............................. Yes, with optional 1U rack shelf
Enclosure type ................................ Metal
Enclosure dimensions ..................... 1.7" H x 8.7" W x 9.5" D (1U high, half rack wide)
(4.3 cm H x 22.1 cm W x 24.1 cm D)
Product weight ............................... 2.5 lbs (1.1 kg)
Shipping weight ............................. 5 lbs (3 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ...................................... CCC, CE, c-UL, GS, KC Mark, PSE, S Mark, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release;
meets UL 60065, IEC 60065, and BSEN 60065 for A/V equipment.
EMI/EMC ................................. CE, CISPR 22 Class B, C-tick, FCC Class B, ICES, VCCI Class B
Environmental .......................... Complies with the appropriate requirements of ENERGY STAR
®
(ENERGY STAR
qualified amplifier), EU code of conduct, RoHS, WEEE
MTBF ............................................. 250,000 hours
Warranty ........................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
XTRA Series Power Ampliers • References 15