User guide

Rear Panel Features and Operation
100-240V 0.5A, 50-60Hz
CLASS 2 WIRING
1
2
XPA 1002
LEVEL
1
12
1
2
LIMITER/
PROTECT
SIGNAL
2
INPUTS OUTPUT
REMOTE
0 0
10V 50 mA
VOL/MUTE
STANDBY
AUDIO/VIDEO
APPARATUS
17TT
XPA 1002
Ç
a
Ñd àf å
100-240V 0.5A, 50-60Hz
VOL/MUTE
STANDBY
80 Hz
L(MONO)
R
CLASS 2 WIRING
XPA 2001-70V
OUTPUT
70V
LEVEL HFP INPUTS
REMOTE
0
10V 50 mA
AUDIO/VIDEO
APPARATUS
17TT
LIMITER/
PROTECT
SIGNAL
XPA 2001-70V
Ç
a
Ñd
100-240V 0.5A, 50-60Hz
AUDIO/VIDEO
APPARATUS
17TT
LIMITER/
PROTECT
SIGNAL
STANDBY
80 Hz
L(MONO)
R
CLASS 2 WIRING
XPA 2001-100V
OUTPUT
100V
LEVEL HFP INPUTS
REMOTE
0
VOL/MUTE
10V 50 mA
XPA 2001-100V
É
a
Öd
Figure 4. XPA 1002/2001 Rear Panel
a
AC power connector — Connect a standard IEC AC power cord here for power input
(100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply. This
connector may be replaced by the Flexible Conduit Adapter Kit (part number 70-228-02)
as described in “Flexible Conduit Adapter Kit Installation” on page 19.
Ç
Limiter/Protect indicator LEDs (channels 1 and 2) — These LEDs (representing
output channels 1 and 2) light red under four circumstances:
12
LIMITER/
PROTECT
When the output wiring is shorted together
When audio clipping occurs, the corresponding channel’s LED blinks once per clip
occurrence.
When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the
amplifier cools down and recovers from the overheated condition.
When DC output is detected, the amplifier is malfunctioning and the LED for the
corresponding channel is lit. When a malfunction occurs, power down the amplifier
and power it back up. If the LED still remains lit, the amplifier requires servicing.
See item
Ñ
of “Front Panel Features and Operation” earlier this section.
XTRA Series Power Ampliers • Installation and Operation 6