User`s manual

XTRA Series • Reference
A-3
Output power
XPA 1002 ............................. 60 watts rms per channel, 8 ohms, 1 kHz,
<0.05% THD
100 watts rms per channel, 4 ohms, 1 kHz,
<0.05% THD
XPA 2001-70V ..................... 200 watts rms, 70 V, 1 kHz, <0.1% THD
XPA 2001-100V ................... 200 watts rms, 100 V, 1 kHz, <0.1% THD
Frequency response ...................... 20 Hz to 20 kHz, ±1 dB
THD + Noise
XPA 1002 ............................. 0.05% @ 20 Hz-20 kHz, 8 ohms, at 3 dB
below clipping
XPA 2001-70V, XPA 2001-100V
<0.1% @ 1 kHz at 3 dB below clipping
S/N
XPA 1002 ............................. 105 dB, 20 Hz - 20 kHz, unweighted
XPA 2001-70V, XPA 2001-100V
100 dB, 20 Hz - 20 kHz, unweighted
Damping factor
XPA 1002 ............................. >100 @ 8 ohms
XPA 2001-70V ..................... >100 @ 25 ohms
XPA 2001-100V ................... >100 @ 50 ohms
High pass lter
XPA 2001-70V, XPA 2001-100V
80 Hz, 12 dB per octave rolloff (switch
selectable)
Control/remote — amplier
Control port .................................... (1) 3.5 mm captive screw connector, 5 pole
Pin configurations
DC volume control (analog)
Pin 1 = +10 VDC, 50 mA (max.), pin 2 =
volume/mute (variable voltage), pin 3 =
GND
Volume control voltage range
0 V (mute) to 10 V (maximum volume)
Standby power control (contact closure)
Pin 4 = GND, pin 5 = standby
General
Power .............................................. 100 VAC to 240 VAC, 50-60 Hz, internal
Typical ................................. 26 watts (1/8 power [pink noise] at 8
ohms)
Quiescent