User`s manual

XTRA Series • Operation
3-7
Do not tin the wires!
Balanced Mono Input
(high impedance)
Tip
Ring
L R
Sleeve
Unbalanced Mono Input
Tip
Sleeve
L R
N
For mono input on the XPA 2001, only the left channel
needs to be wired. No jumpering to the right channel is
needed.
f
Remote control connector — The 3.5 mm 5-pin captive screw
receptacle is used to remotely control two functions through
contact closure: See the following circuit diagram.
Pins 1, 2, and 3 control volume by varying the DC voltage
from 0 V (full attenuation) to 10 V (maximum volume) with
full muting in effect when pin 2 is connected to ground (pin3).
Use the included 3-pin captive screw connector. See "Remote
volume control" in this chapter.
MUTE
VOLUME
GND
10K OHMS
2K OHMS
MAX
2 VOL/MUTE
3
1 10 V
MIN
123
STANDBY
MUTE SWITCH
VOL/MUTE
10V 50 mA