User`s manual
XTRA Series • Installation
2-9
10. Connect the black hot (line) and white neutral wires to the
terminal block on the PCB using the 2 screws that were
removed in step 3. Use the included zip tie wrap to secure
the two wires together close to the terminals. See the
following illustration.
W
Ensure that you observe correct wire polarity. The
following illustration shows the location of the hot
(L) and neutral (N) terminals.
LINE
NEUTRAL
L
N
Conduit Nut
EMT Adapter Plate
Te rminal Block
Zip-Tie
Ground
Wire Nut
Hot
Te rminal (Black)
Neutral
Te rminal (White)
11. Connect the ground wire, as shown above, to the
grounding stud on the bottom of the enclosure using the
nut that was removed in step 4.
12. Replace the cover of the XPA by attaching the 8 screws that
were removed in step 2.