User`s manual

XTRA Series • Installation
Installation, cont’d
2-8
100-240V 0.5A, 50-60Hz
STANDBY
CLASS 2 WIRING
1
2
XPA 1002
LEVEL
1
1
2
2
INPUTS
OUTPUT
REMOTE
0
0
VOL/MUTE
10V 50 mA
1 2
LIMITER/
PROTECT
SIGNAL
AUDIO/VIDEO
APPARATUS
17TT
Remove (8)
screws
Lift Cover Straight Up
3. Remove the 2 screws holding the hot (line) and neutral
wires from the terminal block on the PCB.
100-240V 1.3A
50-60Hz
Remove screws
(both sides) to release
IEC connector plate.
Remove nut
Blue Wire
Brown Wire
L
N
4. Remove the ground wire nut from the grounding stud on
the bottom of the enclosure, as shown above.
5. Remove the 2 screws from the IEC plate, and remove the
IEC connector plate and the attached wires through the
rear panel of the XPA, as shown above.
6. Thread the 18-gauge power wires through the length of the
electrical conduit tube.
7. Install the EMT adapter plate with conduit attached into
the opening from which the IEC connector was removed.
in step 5.
8. Slide the conduit nut over the bundle of wires exiting the
conduit and onto the conduit itself. Hand tighten the
conduit nut to the conduit.
9. Attach the EMT adapter plate assembly to the XPA using
the 2 screws that were removed in step 5.