Operating instructions

Special Application, cont’d
VoiceLift Microphone • Special Application
4-4
PRELIMINARY
4. Using Global Congurator on your computer, congure the MLC’s Digital
I/O port for digital input with pull-up.
Global Configurator screen for configuring the MLC’s Digital I/O port
5. Use Global Congurator to congure a monitoring device to send an e-mail
when the MLC’s Digital I/O port closes.
(Refer to the Global Congurator help le for procedures to congure the
MLC’s Digital I/O port and the monitor using Global Congurator.)
6. Test the instant alert notification as follows:
a. Make sure that the MLC 104 IP Plus is connected to the network.
b. Make sure that channel A or B has been selected for the microphone.
c. Press and hold both sections of the Volume button on the microphone
simultaneously for 2 seconds. The LED in the receiver dome blinks
alternating amber and green.
Press and hold both
sections of the
Volume button
simultaneously.
d. Check for the arrival of the e-mail notification.