Installation guide
1. Connect the receiver to the 
MLC 104 IP Plus.
a.  Wire one of the provided two-pole captive screw 
connectors to one end of a communication cable.
b. Plug the communication cable into the receiver’s RLY 
port.
N
  If the MLC controller and the PoleVault switcher 
  are using separate power supplies, ground the  
 Relayportcommonpintothereceiverusinga
  jumper between the common pin and the ground 
 pinoneithertheContactinput,theAuxInput,or
 theRS-232port. 
c.  Pull the communication cable to the MLC 104 IP Plus 
location.
d. Connect the other end of the cable to a direct-insertion 
Digital I/O port on the MLC:
  •  Insert the black wire into the Ground port.
  •  Insert the red wire into the rst available Digital I/O  
  port.
Installation Example — Setting Up an Instant Alert
The following pages describe an example of an optional instant alert setup, in which the relay port of the VLR 102 
is connected to a digital I/O port of an Extron MLC 104 IP Plus. This enables e-mail alerts to be sent out when both 
Volume buttons of the VLP 102 microphone are pressed and held for 3 seconds. 
û 
Connect the communication cable to 
  an MLC Digital I/O port.
Å
 Connect a communication cable to the  
  VLR 102 RLY port.
For separate power supplies, jumper-
connect the C pin of the Rly port to the 
ground pin of the CTC, Aux In, or RS-232 
port.
VoiceLift Microphone Installation • Optional Installation Example — Instant Alert
2-16
Optional Installation Example — Instant Alert