User Guide Owner's manual

VN-QUANTUM User Guide Section 5: Technical Data
I455GB issue 8 Page 95
Control Inputs/Outputs
The following control input/output connectors appear on the ES3301-2 and ES3302 / 3304 Card
Frames.
CONTROL Port
Function:
Connection to a VN-COMMANDER control PC.
Connector Type:
Shielded RJ-45 Socket.
Pin-out Details:
Pin Function Pin Function
1 TX_D1+ (TX+ ) 5 BI_D3–
2 TX_D1– (TX– ) 6 RX_D2– (RX– )
3 RX_D2+ (RX+) 7 BI_D4+
4 BI_D3+ 8 BI_D4–
Mating Connector:
Shielded RJ-45 Plug.
Recommended Cable:
Shielded twisted pair (STP).
Max. Cable Length:
100 metres (330 feet).
Comms Standard:
10/100BASE-T (Fast Ethernet)
Default IP Address:
Factory-set to 172.28.232.11. No DHCP option.
User-definable via control software.
MEDIA I & II Ports (Not supported on the ES3304 VN-QUNATUM CONNECT)
Function:
Connection to a local or wide area network for access to network
content or VN-GLIMPSE sources.
Connector Type:
Shielded RJ-45 Socket.
Pin-out Details:
Pin Function Pin Function
1 BI_DA+ 5 BI_DC-
2 BI_DA- 6 BI_DB-
3 BI_DB+ 7 BI_DD+
4 BI_DC+ 8 BI_DD-
Mating Connector:
Shielded RJ-45 Plug.
Recommended Cable:
Shielded twisted pair (STP).
Max. Cable Length:
100 metres (330 feet).
Comms Standard:
1000BASE-T (Gigabit Ethernet)
Default IP Address:
Factory-set to DHCP operation.
Fixed IP address user-definable via control software.