User Guide Owner's manual

2. In the Reset Options screen, use the right rotary encoder to select which type of reset
you want. You can choose Factory IP or Sanitize:
Factory IP — restores the following parameters to the factory default:
z IP address
z Subnet mask
z Gateway IP address
z Controller IP address
z Link speed set to auto
z Static IP address
z Controller port number
For factory default values see figure 11 on page 24.
Sanitize — runs the sanitize process to overwrite volatile scaler memory (for the
on‑screen display), volatile Wavelet memory, and all non‑volatile memory. All these
memory locations are overwritten three times:
z Firstly with a random pattern of zeroes and ones.
z Secondly with binary zeroes.
z Thirdly with binary ones.
3. Use the left rotary encoder to toggle between Activate or Cancel.
4. Press Next.
5. If you selected Activate in step 3, one of the reset processes runs. The screen shows
System Reset in Progress.
6. When the reset is complete, press Next to return to Decode Config sub-menu (see
page102).
VNM 250 • Front Panel Menu Configuration 110