User’s Manual Extender Series VGA–UXGA Line Drivers With Audio 68-552-01 Rev.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
安全须知 • 中文 警告 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备 必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。 这个符号警告用户该设备机壳内有暴 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 或桌面电源的电源线,或任何接到市电系统的电源线。 露的危险电压,有触电危险。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解所有安全和使用说明。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没 有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 机内敏感元件过热。 不要用任何东西挡住通风孔。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与 厂家推荐的相同
Table of Contents About this Manual ..................................................................... 1-2 About the Extender Series VGA Line Drivers . .................. 1-2 Differences between the models ........................................... 1-2 Features ................................................................................... 1-3 Chapter Two • Installation ...................................................... 2-1 UL Guidelines ........................................................
P R E L IMIN A RY Table of Contents, cont’d Extender AKM UK dimensions .............................................A-14 Extender AKM MAAP dimensions .......................................A-15 Extender D dimensions .........................................................A-16 Templates ....................................................................................A-17 Extender WM template ........................................................A-17 Extender WM AAP template ..........................
Extender Series 1 Chapter One Introduction About this Manual About the Extender Series VGA Line Drivers
P R E L IMIN A RY Introduction About this Manual This manual contains information about the Extron Extender series line drivers, and on how to operate and configure them. “Extender” or “line driver” are used to refer to all models interchangeably when instructions apply to more than one model. About the Extender Series VGA Line Drivers The Extron Extender Series are one-input VGA–UXGA line drivers with audio.
Features Video signal boosting — The selectable gain/peaking settings boost video signals to compensate for signal degradation caused by long cables. The Extender can send a high resolution signal up to 250 feet (75 m) through Extron’s M59 Series mini high resolution cable. Sync restoration — Each Extender restores low level sync voltages found on many laptop PCs (as low as two volts) to normal TTL levels. Audio buffering — Unbalanced stereo audio inputs can be output as balanced audio for long cable runs.
P R E L IMIN A RY Introduction, cont’d 1-4 Extender Series • Introduction
Extender Series 2 Chapter Two Installation UL Guidelines Installation Instructions Preparing the Site and Installing the Wall Box Front Panel Features and Cabling Top/Rear/Bottom panel Features and Cabling Mounting the Extenders Application Diagrams
P R E L IMIN A RY Installation C Installation and service must be performed by authorized personnel only. This product should be used with a UL approved electrical box. See “UL Guidelines”, below. UL Guidelines 1. The Extender must be installed in an Underwriters Laboratories (UL) listed junction box. The UL approved electrical wall box (junction box) is not included with the unit; the installer is responsible for obtaining and installing the box. 2.
• The Extender AAP EX is usually installed into an HSA 400 Series or HSA 800 Series surface access enclosure. • The Extender WM can be installed in a standard or compact one-gang electrical wall box. This is also true for the Extender D, though it requires a standard Decora©-style wall plate. • The Extender WM AUS can be installed in a standard or compact Australian one-gang electrical wall box.
P R E L IMIN A RY Installation, cont’d Metal Wall Box Screw Cable Clamp Braided Shield Install Cable Foil Shield Grounding outer braided and foil shields W To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable. 7. Insert the wall box into the opening, and attach it to the wall, stud, or furniture. 1-gang wall box.
If attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts. • For the Extender MK, pull the knockout box’s mounting tabs forward to secure them against the back side of the wallboard or furniture as shown in the following illustration. Pull mounting tab forward. Securing the MK knockout box to a wall or furniture 8. Set the gain switch, and cable and test the line driver before fastening the line driver into the wall box.
P R E L IMIN A RY Installation, cont’d Front Panel Features and Cabling AUDIO IN COMPUTER IN 6 EXTENDER MK EXTENDER AKM MAAP 1 2 3 4 1 1 AUDIO IN COMPUTER IN 2 3 AUDIO IN COMPUTER IN 4 EXTENDER WM AUS a Faceplate screws — These secure the faceplate to the rest of the line driver. Faceplate dimensions are provided in the appendix of this manual.
P R E L IM IN A RY EXTENDER AUDIO IN COMPUTER IN 1 4 3 AUDIO IN COMPUTER IN 1 2 EXTENDER AKM UK AAP 1 1 5 1 2 AUDIO IN AUDIO IN 3 COMPUTER IN COMPUTER IN 4 1 EXTENDER WM AAP EXTENDER WM c 2 AUDIO IN 3 COMPUTER IN 4 d e Audio input connector — Plug a 3.5 mm stereo plug into this jack for unbalanced audio input. Wire the male plug as shown in the figure at right. Tip (L) Ring (R) Sleeve ( ) 3.
Installation, cont’d P R E L IMIN A RY Other adapter plates must be ordered separately. They also must be attached to the faceplate and cabled before the line driver is installed in the wall or furniture. The screws needed for installing the adapter plates are built into the plates, so no additional screws are needed. 1. Remove the blank plates from the Extender by unscrewing the nuts that fasten the plates to the faceplate. 2. Insert the adapter plate screws through the holes in the faceplate.
Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS, Extender AKM UK AAP, and Extender AKM MAAP top view Extender WM, Extender WM AAP, and Extender D 3 rear view 1 2 1 Extender MK/AAP/AAP EX, Extender AKM UK AAP, Extender AKM MAAP, Extender WM AUS rear view 1 2 4 (Side) 3 4 Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS, Extender AKM UK AAP, and Extender AKM MAAP bottom view a b c d Audio output connector — page 2‑10 3 RGB video output connectors — page 2‑11 Power connector —
Installation, cont’d P R E L IMIN A RY a Audio output connector — Insert wires into and tighten the screws on this 3.5 mm, 5-pole direct insertion captive screw connector for unbalanced or balanced audio output. Wire the connector as shown in the following illustrations. Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative (-) terminal will damage the audio output circuits. C CAUTION L Audio R For unbalanced audio, connect the sleeve(s) to the ground contact.
L Audio R For unbalanced audio, connect the sleeve(s) to the ground contact. DO NOT connect the sleeve(s) to the negative (-) contacts.
Installation, cont’d P R E L IMIN A RY d Gain switch — 4 Medium – Mid-level peaking and gain Normal Unity gain Maximum Max. peaking and gain Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS, Extender AKM UK AAP, and Extender AKM MAAP gain switch location (access from the rear) Faceplate 4 Medium – Mid-level peaking & gain Maximum Normal Max.
Normal — unity gain (no signal boost) Medium — mid-level peaking and gain Maximum — maximum amount of peaking and gain. Select this for use with longer cables. N Adjust the gain before installing the Extender into a wall, furniture, or equipment, as the gain switch will be inaccessible after installation.
P R E L IMIN A RY Installation, cont’d Mounting the Extenders Mounting the Extender AAP or Extender AAP EX into an AAP wall plate or device faceplate The Extender AAP or Extender AAP EX and any other adapter plates must be attached to a device faceplate or AAP wall plate and cabled before the device or wall plate is pretested or installed in a wall or furniture. 1.
P R E L IM IN A RY Extron HSA 822 Two Screws Each Side Front Panel AU D IO IN CO MP UT ER HS A 82 2 IN Extron Extender AAP EX Cable #4-40 Nut w/ Captive Washer HV - 18” RGB - 20” Connects to AAP Cable Mounting the Extender AAP EX to an HSA faceplate 4. Repeat steps 1, 2, and 3 to mount other AAPs. Cover any openings in the faceplate with blank plates (provided). 5. Be sure to include the AAP connectors as part of the installation pretest before final installation of the faceplate.
Installation, cont’d P R E L IMIN A RY Pre-installation testing/troubleshooting Before mounting the line driver, test the system to make sure that the connections and settings are correct. 1. Apply power to the line driver. The power/signal LED on the line driver lights amber to indicate that it is receiving power. 2. If the LED does not light, check the wiring at both the line driver and the power supply, and make sure the power supply is connected to a power source.
1. Remove power from the line driver by disconnecting the power supply. 2. Place the line driver through the opening in the wall or furniture and into the wall box. Take care not to damage the output cables, which fit behind the line driver at the back of the wall box. 3. Mount the line driver’s faceplate to the wall box with machine screws as shown in the following illustration. Extender WM AAP Install.
Installation, cont’d P R E L IMIN A RY Mounting the Extender D 1. Remove power from the line driver by disconnecting the power supply. 2. Place the Extender D through the opening in the wall or furniture and into the wall box. Take care not to damage the output cables, which fit behind the line driver at the back of the wall box. 3. Mount the Extender D to the wall box with machine screws as shown in the following illustration. Wall Box DIO AU Wall opening is flush with edge of box.
1. Remove power from the line driver by disconnecting the power supply. 2. Place the line driver through the opening in the wall or furniture and into the knockout box. Take care not to damage the cables, which lie next to the line driver at the side of the box. 3. Extender MK Box Exploded_021209.eps Mount the line driver’s faceplate to the knockout box with machine screws as shown in the following illustration. M59 Cable Double Wide Dry Lining Box 3.
P R E L IMIN A RY Exterder WM.eps Installation, cont’d Application Diagrams Mini HR Cable Projector Wall Stud Audio AU DIO Laptop w/ Audio IN R IN TE MPU CO ER WM ND TE EX Extender WM Mini HR Cable Projector Laptop w/ Audio UT MP ER IN CO DIO AU H.
Extender Series A Appendix A Reference Specifications Ordering Information Accessories Dimensions Templates
P R E L IMIN A RY Reference Specifications Video Gain ������������������������������������������������� 0 dB, 0.6 dB, 1.2 dB, selectable (when input is 0.7 Vp-p, output is 0.7 V, 0.75 V, 0.8 Vp-p) Bandwidth �������������������������������������� 300 MHz (-3 dB) N ID bits are terminated (pins 4 and 11).
P R E L IM IN A RY Sync Input type ��������������������������������������� RGBHV, RGBS, RGsB, RsGsBs, bi-level and tri-level component video sync Output type ������������������������������������ RGBHV, RGBS, RGsB, RsGsBs, bi-level and tri-level component video sync Input level �������������������������������������� 2.0 V to 5.
P R E L IMIN A RY Reference, cont’d Nominal level �������������������������������� -2 dBu, balanced; -10 dBV unbalanced Maximum level (Hi-Z) ����������������� +14 dBu, balanced, at 1% THD+N Maximum level (600 ohm) ����������� +6 dBm, balanced, at 1% THD+N N 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu General External power supply ����������������� 100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 1 A (max.), regulated Power input requirements ����������� 12 VDC, 0.
Extender Series • Reference A-5 P R E L IM IN A RY Extender WM Faceplate ��������������������� 4.5" H x 2.8" W x 0.1" D (11.4 cm H x 7.1 cm W x 0.3 cm D) (1 gang) Buffer ��������������������������� 2.7" H x 1.8" W x 0.75" D* (6.9 cm H x 4.6 cm W x 1.9 cm D*) (*Depth excludes BNC connectors and cables.) Extender WM AUS Faceplate ��������������������� 3.0" H x 4.7" W x 0.1" D (7.6 cm H x 11.8 cm W x 0.3 cm D) Buffer ��������������������������� 2.75" H* x 1.1" W x 1.2" D (7.0 cm H* x 2.8 cm W x 3.
P R E L IMIN A RY Reference, cont’d Extender D Faceplate ��������������������� 2.6" H* x 1.3" W x 0.1" D (6.6 cm H* x 3.3 cm W x 0.3 cm D) (Fits the opening in a 1 gang Decora faceplate. *Height is 3.8" [9.7 cm] including mounting tabs.) Buffer ��������������������������� 2.7" H x 1.8" W x 0.75" D* (6.9 cm H x 4.6 cm W x 1.9 cm D*) (*Depth excludes BNC connectors and cables.) Product weight Extender AAP, Extender AAP EX, Extender WM 0.2 lbs (0.1 kg) Extender WM AUS ������������ 0.3 lbs (0.
This section lists part numbers for each Extender and Extender kit.
P R E L IMIN A RY Reference, cont’d Mud rings/mounting brackets Part numbers MR 100 – 1-gang modular plastic mud ring (black, white) 70-519-12, -13 MR 100D – 1-gang Decora®-style modular plastic mud ring (black) 70-581-12 MR 300 – 3-gang modular plastic mud ring (black, white) 70-519-32, -33 MR 300D – 3-gang Decora®-style modular plastic mud ring (black) 70-581-32 MK 2-gang metal mounting bracket/ mud ring (black, white, RAL9010 white 70-086-16, -26, -56 Miscellaneous cables Part numbers Cabl
P R E L IM IN A RY Dimensions N The drawings in this section are not full size. Do not scale. N All dimensions are given in inches. Extender AAP and Extender AAP EX dimensions 0.250” (REF) 3.000” (REF) 0.050” (REF) DETAIL A ø 0.125 THRU WITH ø 0.220 X 100° C'SINK NEAR SIDE (2 PLACES) ø 0.250” THRU ø 0.125” THRU R 0.040 (TYP) 1.400 1.045 AUDIO IN COMPUTER IN 0.700 (REF) 0.650 0.345 0.345 (REF) 3.500 3.250 2.917 2.125 0.984 ø 0.125 THRU (2 PLCS) 0.
Reference, cont’d P R E L IMIN A RY Extender WM dimensions 2.790 1.395 0.000 ø 0.156 THRU WITH ø 0.290 X 82° C'SINK (2 PLACES) 0.000 0.610 1.107 ø 0.125 THRU 1.550 AUDIO IN 2.010 COMPUTER IN 2.570 3.392 3.890 EXTENDER WM 4.500 A-10 Extender Series • Reference ø 0.330 THRU WITH ø 0.562 C'BORE 0.
0.000 0.610 1.107 1.550 1.930 2.490 2.950 3.393 3.890 4.500 SECTION A–A 2.780 2.650 2.390 0.000 Extender Series • Reference 0.060” 0.060” C COMPUTER IN AUDIO IN C EXTENDER WM AAP C C A 0.000” 1.900” ø 0.170” (8 PLCS) 1.200” 2.600” 3.300” R 0.240” (TYP) 4.500” +0.003 0.050 -0.000 6.400 R 0.070" TOP EDGE (ALL AROUND) ø 0.125” THRU WITH ø 0.220” X 100° C'SINK NEAR SIDE (2 PLACES) DETAIL B A ø 0.330” THRU WITH ø 0.562” C'BORE 0.070” DEEP ø 0.125” THRU +0.010 3.520 -0.
Extender WM AUS dimensions Ø 0.125” THRU Ø 0.250” THRU 3.000” AUDIO IN COMPUTER IN EXTENDER WM AUS 2X Ø 0.125” THRU Ø 0.220” X 100° A-12 Extender Series • Reference 4.650 3.979 3.493 2.228 1.840 1.434 1.157 0.671 0.000” 0.
0.060 0.100” THICK 0.060” 0.000 1.690 3.380 R 0.070” TOP EDGE (ALL AROUND) R 0.040” (TYP) ø 0.125” THRU ø 0.250” THRU 2.365 1.681 1.460 1.958 0.474 0.000 +0.003 C'BORE 2.780 x 1.070 x 0.050 -0.000 DEEP (C’BORE FAR SIDE) COMPUTER IN 3.244 AUDIO IN 0.806 ø 0.156” THRU WITH ø 0.290” X 100° C'SINK (2 PLCS) 10° (2 PLCS) ø 0.125” THRU (2 PLCS) 0.984” DETAIL A ø 0.125” THRU WITH ø 0.220” X 100° C'SINK NEAR SIDE (2 PLCS) EXTENDER MK DETAIL A 0.449” 0.
A-14 3.000” Extender Series • Reference #4-40 THREADED Ø 0.125” THRU 3.898” 3X 3.768” 0.272” 0.457” 0.000” (7.156) 6X Ø 0.180” THRU 6.638” 2X Ø.125” THRU w Ø.272” x 100° MARKED B Ø 0.250” THRU B B 3X 6.768” R 0.030” (TYP) 4X R 0.060” 2X 0.800” 10° (2 PLCS) 0.806 0.984 ROTATED 90° C.W. DETAIL A 0.445” +0.020” 2.110 -0.000” Ø 0.174” THRU 2X 2.200” ø 0.125 THRU (2 PLCS) 7.613” 7.428” 0.590” 0.000” 0.325” 0.610” 1.016” 4X 1.500” 1.895” 2.
4X R 0.125” 2X 0.06” X 45° 2X R +0.000 3.000 -0.015 2X R 0.062 A 2X 2.350 2X 2.250” 1.975 1.750 2X Ø 0.150” THRU 1.250 1.025 A 2X 0.750” 2X 0.650 2X 2.250 0.000 2X 1.050 3.100 3X 5.000 6.020±020 5.750 2X 5.713 5.375 2X 5.249 0.000” 1.675 0.275 0.000 (0.
Reference, cont’d P R E L IMIN A RY Extender D dimensions 1.290” 2X 0.062” X 45° 0.333” 0.625” 0.223” 0.399” 2X Ø 0.106” THRU BOTH SIDES 2X 0.111” 2X EXTRUSION FOR #6-32 SCREW TAPPING 2X 0.125” Ø 0.132” THRU 2.610” (0.223”) Ø 0.258” THRU 2.005” 1.545” 0.984” 0.905” 0.359 0.000” A-16 1.290” 7X 0.645” 0.000” 0.111” Extender Series • Reference 0.
P R E L IM IN A RY Templates N Always check and use the dimensions given in this appendix. Extender WM template Cut-Out Template for the Extron Extender WM 2.79" (7.09 cm) Top Panel 2.24" (105 cm) 4.50" (11.43 cm) 4.13" (57 cm) Location of Extender AAP Circuit Board SURFACE CUT-OUT AREA FOR MOUNTING Cut Out Line for Installing the Electrical Box TEMPLATE IS FULL SIZE. Please verify dimensions prior to cutting.
P R E L IMIN A RY Reference, cont’d Extender WM AAP template Cut-Out Template for the Extron Extender WM AAP 4.5” (11.43 cm) Location of Extender AAP Circuit Board 3.86” (9.80 cm) 6.4" (16.3 cm) 5.73” (14.55 cm) Top Panel SURFACE CUT-OUT AREA FOR MOUNTING Cut Out Line for Installing the Electrical Box TEMPLATE IS FULL SIZE. Please verify dimensions prior to cutting.
P R E L IM IN A RY Extender MK template Cut-Out Template for the Extron Extender MK 3.38" (8.56 cm) Top Panel 1.85" (4.70 cm) 5.70" (14.48 cm) 2.91" (7.40 cm) Location of Extender Circuit Board SURFACE CUT-OUT AREA FOR MOUNTING To install an Extender MK directly into furniture, cut along this line. TEMPLATE IS FULL SIZE. Please verify dimensions prior to cutting.
Reference, cont’d P R E L IMIN A RY Extender WM AUS template Cut-out Template for the Extron Extender WM AUS 3.00" (7.62 cm) Top Panel 1.85" (4.70 cm) 4.65" (11.81 cm) 2.91" (7.40 cm) Location of Extender Circuit Board SURFACE CUT-OUT AREA FOR MOUNTING To install the Extender WM AUS directly into furniture, cut along this line. TEMPLATE IS FULL SIZE. Please verify dimensions prior to cutting.
Extron’s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase.
Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.