User`s manual
VersaTools
®
MTP 15HD RS Series • Installation
VersaTools
®
MTP 15HD RS Series, cont’d
VersaTools
®
MTP 15HD RS Series • Specications
Control/remote — external device (pass-through,
unidirectional or bidirectional)
Serial control port input/output
MTP C7 T 15HD RS, MTP T 15HD RS
RS-232 via (1) 3.5 mm, 3 pole captive
screw connector
Receivers
............................. 1 set of proprietary signals on a female
RJ-45 jack
Serial control port output/input
MTP C7 T 15HD RS, MTP T 15HD RS
1 set of proprietary signals on a female
RJ-45 jack
MTP C7 RL 15HD RS, MTP C7 RL 15HD RS SEQ, MTP RL 15HD RS,
MTP RL 15HD RS SEQ
RS-232 via a 3.5 mm, 3 pole captive screw
connector
The serial communications link of an MTP C7 RL 15HD RS,
MTP C7 RL 15 HD RS SEQ, MTP RL 15HD RS, or MTP RL
15 HD RS SEQ is unidirectional only, transmitter to receiver,
unless the receiver’s directional jumper has been repositioned.
The jumper should be repositioned only when the receiver is the
only one in the system.
Baud rates ...................................... Up to 38400 bps at up to 600' (183 m)
(Higher data rates and distances are
possible. Performance will vary based on
baud rate and cable length.)
Protocol
........................................... Data bits = 5 - 8
Stop bits = 1 or 2
Parity = odd, even, none
Flow control = XON, XOFF, none
Protocol is mirrored between the transmitter and the receiver.
Serial control pin congurations . Captive screw connectors: 1 = TX, 2 = RX,
3 = GND
26