User’s Manual RGB 130xi, 134xi, 160xi, 164xi Universal Interfaces www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • Introduction ......................................................... 1-1 About this Manual ................................................................ 1-2 About the Interfaces ............................................................ 1-2 Features ...................................................................................... 1-2 Chapter 2 • Controls and Installation ........................... 2-1 Front Panel Features ......................................
Table of Contents, cont’d xi xi xi xi RGB 130xi xi, 134xi xi, 160xi xi, 164xi Page intentionally left blank 1 Chapter One Introduction About this Manual About the Interfaces Features ii xi xi xi xi • Table of Contents RGB 130xi xi, 134xi xi, 160xi xi, 164xi
Introduction About this Manual This manual documents four universal interfaces: RGB 130xi, RGB 134xi, RGB 160xi, and RGB 164xi. Unless otherwise specified, any references to “the interface” shall refer to the features or operation of all four interfaces. About the Interfaces The RGB 130xi, 134xi, 160xi, and 164xi are universal interfaces with a video bandwidth of 300 MHz and a horizontal frequency range of 15-160 kHz.
Controls and Installation RGB 160xi and RGB 164xi — HD 15-pin female analog video input connector. Front Panel Features RGB 130 UNIVERSAL INTERFACE W/ADSP INPUTS ANALOG/ECL MBC 2 3 MBC power (RGB 130xi and RGB 134xi only) — 2.5 mm jack provides power for MBC buffer. 5 ID bit termination DIP switches (RGB 160xi and RGB 164xi only) — Provides proper ID bit termination on the local monitor output for a laptop computer that is not attached to a local monitor.
Controls and Installation, cont’d 0.5A MAX. GAIN/ PEAK 100% SOG DDSP SERR 75 Ohm 100-240 R G B R G B H V S H V S 1 If desired, mount the interface to an equipment rack (RGB 164xi only) or to or through a desk or other suitable surface using Extron’s optional mounting kit. See Mounting the interface in the next section. 2 Turn off power to the computer and its monitor. Turn off power to the projector or display device. Disconnect the power cord from the interface.
Controls and Installation, cont’d AUD IO INPU ID PIN 4 ID PIN 11 T UNI VER SAL INTE H. SHIF T RFA RGB CE 160 xi W /AD SP RGB 160 Figure 2-10 — Attaching the under desk brackets Through desk mounting False Front Panel uses 2 front holes Mount the interface through a desk or table, as follows: 1. DI O INPU T ID PIN 4 ID PIN 11 AU Attach the mounting brackets to the interface using four machine screws and washers (supplied with the mounting kit), as indicated in figure 2-11.
Controls and Installation, cont’d Cabling Each interface can connect to the computer or workstation’s local monitor, either directly or using an MBC cable, and to a projector or other display device. Rear Figure 2-12, and figure 2-14, figure 2-15, and figure 2-16, on the next two pages, show how to connect each of the interfaces. Front AU DI O INPU T MBC PO W ER H. SH IFT UN IVER SA L IN TE RF RGB AC E W 134 xi SH /ADS IFT P MIN/ MA X Projector SOG OUT DDSP SERR SPARE H. A 0.
Controls and Installation, cont’d Tip See warning Sleeve(s) Tip See warning Unbalanced Output Rear AU DI O UN IVER SA L IN TE RF RGB AC E W 164 xi SH /ADS IFT P H. Connect the sleeve(s) to ground (GND). Connecting the sleeve(s) to a negative (-) terminal will damage audio output circuits. Projector 0V -24 100 L/ VE LE AK PE 50% V 0.8 SOG OUT DDSP SERR SPARE UT A 0.5 TP OU Output 2 ITY UN % V 100 0.
Controls and Installation, cont’d Off — If this switch is set to Off, the interface performs sync processing operations, such as horizontal shift, using Extron’s ADSP™. Turning on the DDSP feature disables the horizontal shift control and the vertical shift control. SERR (serration pulses) Follow these steps to change the jumper settings. The RGB 134xi is shown for illustration, but the steps apply to all interfaces. 1. Remove power from the interface by disconnecting the AC power cord from the unit. 2.
Controls and Installation, cont’d xi xi xi xi RGB 130xi xi, 134xi xi, 160xi xi, 164xi Pin 1 to Pin 2 Pin 2 to Pin 3 Rear 1 J19 1 J20 J20: Sync polarity jumper 1 J40 J40: Vertical sync width jumper Power Supply A Appendix A Front Figure 2-19 — Circuit board jumper locations Figure 2-20 — Changing jumper settings J40: Vertical sync width jumper — This jumper adjusts the vertical sync pulse width.
Specifications, Part Numbers, and Templates Specifications Sync Video Gain ............................................... Unity, (0.725V p-p) 50% peaking, (0.75V p-p) 100% peaking Bandwidth .................................... 300 MHz (-3dB) Video input Number/signal type ................... 1 analog RGBHV, RGBS, RGsB, RsGsBs Connectors .................................... RGB 130xi, RGB 134xi ............... 1 9-pin D male RGB 160xi, RGB 164xi ............. 1 15-pin HD female Minimum/maximum levels ...
Specifications, Part Numbers, Templates, cont’d General Accessories and Part Numbers Power ............................................. 100VAC to 240VAC, 50/60 Hz, 15 watts, internal, auto-switchable MBC power jack ........................... 9.0VDC, 150 mA Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing Operating +32° to +104°F (0° to +40°C) / 10% to 90%, non-condensing Rack mount ...................................
Specifications, Part Numbers, Templates, cont’d Signal input cable kits for RGB 160xi, RGB 164xi VGA M6’ MHR 26-238-15 VGA M3’ MHRA 26-490-01 VGA M6’ MHRA 26-490-02 VGA M12’ MHRA 26-490-03 Mac Adapter kit with Audio 70-156-01 13W3 Adapter cable kit with Audio 70-157-01 BNC cables BNC-5 3’ HR 26-260-15 BNC-5 6’ HR 26-260-01 BNC-5 12’ HR 26-260-02 BNC-5 25’ HR 26-260-03 BNC-5 50’ HR 26-260-04 BNC-5 75’ HR 26-260-16 BNC-5 100’ HR 26-260-05 BNC-5 3’ HRP 26-378-01 BNC-5 6’ HRP 26-378
Specifications, Part Numbers, Templates, cont’d RGB 134xi and RGB 164xi Under-Desk Mounting Bracket Dimensions A-8 xi xi xi xi • Specifications, Part Numbers, RGB 130xi xi, 134xi xi, 160xi xi, 164xi and Templates xi xi RGB 130xi xi, 134xi xi, 160xxi, 164xxi • Specifications, Part Numbers, and Templates A-9
Specifications, Part Numbers, Templates, cont’d RGB 134 and RGB 164 Through Desk Mounting Bracket Dimensions A-10 xi xi xi xi • Specifications, Part Numbers, RGB 130xi xi, 134xi xi, 160xi xi, 164xi and Templates