CAUTION: Do not tin the stripped power supply leads before inserting them into
the captive screw connector. Tinned leads are not as securely attached
as untinned leads and could slip out.
NOTE: Both transmitter and receiver have remote power capability. For transmission
distances up to 300 feet, the power is required only at either the transmitter
or the receiver. Greater distances will require power to be applied to both
transmitter and receiver.
É Power input jack — Connect the included 12 VDC external power supply to this
female jack. The VTT001 and the VTR001 use this power input connector (see the note,
caution, and warning for
Ç above).
The male power plug that connects to this input jack is shown
Power Connector wiring.eps
Tip (+)Sleeve Tip (+)
Sleeve
Power plug
on the right.
CAUTIONS: Always use a power supply supplied by or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance
certification and may cause damage to the supply and the end
product.
Unless otherwise stated, the AC/DC adapters are not suitable for
use in air handling spaces or in wall cavities. The power supply is
to be located within the same vicinity as the Extron A/V processing
equipment in an ordinary location, Pollution Degree 2, secured to
the equipment rack within the dedicated closet, podium or desk.
The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and
the Canadian Electrical Code part 1, section 16. The power supply
shall not be permanently fixed to building structure or similar
structure.
VTT001 and VTR001 User Guide • Installation 5