User`s manual

TP Receivers • Installation and Operation
Installation and Operation, cont’d
2-18
Cable testing
The TP units are designed for and perform best with Extron
Enhanced Skew-Free A/V cable terminated in accordance
with the TIA/EIA T 568 A wiring standard. CAT 5, Cat 5e and
Cat 6 cables are acceptable but less preferable. Extron also
recommends the use of pre-terminated and tested cables. Cables
terminated on site should be tested before use to ensure they
comply with Category 5/5e/6 specifications.
Equalizing pair skew
CAT 5/5e/6 TP cable can lead to registration errors between the
red, green, and blue video signals. Pair skew can be measured
with test equipment or identified by viewing a crosshatch test
pattern with a critical eye to determine if either the red, green,
or blue video image leads (appears to the left of) the other two
video images.
N
Unless the cable is replaced, the skew adjustment is only
done once during installation.
Try using the following methods to minimize or eliminate pair
skew:
Switch to Enhanced Skew-Free A/V UTP cable.
Add a skew compensation cable to the receiver
output equal to the length of pair skew.
Install an SEQ 100 15HD Skew Equalizer on the
video output of the receiver and adjust the skew for
the leading video image.