Updating Firmware from a Web Browser
1. Power on a computer that is connected to the same network as the TLP 710.
2. From the Extron website (www.extron.com), download the firmware for the
touchpanel.
a. Click the Download tab on the Extron home page
b. Select the Firmware option (see figure 23).
c. Navigate to the touchpanel firmware and click Download.
This downloads the firmware to your computer. Note the folder in which the firmware
file is saved.
3. In the address field of your browser, type the IP address of the TLP 710 unit. The
browser opens the TouchLink panel web pages (see page19).
1
2
3
4
Figure 25. Firmware Upgrade Web Page
4. Click the Configuration tab (Figure 25,
a
) at the top of the page and then select
Firmware Upgrade (Figure 25,
b
) from the sidebar on the left.
5. Click the Browse button (Figure 25,
c
) and navigate to the firmware file that was
saved in step 2.
6. Click Upload (Figure 25,
d
). The Touchpanel screen shows the message “Firmware
Uploading... Please Wait...”. When the firmware is uploaded, the screen shows the
message “Restarting...”. Once the firmware is installed, the panel can be calibrated
using the on-screen menus (see page 14) or the TouchLink panel web pages
(see page19).
TLP 710MV and TLP 710TV • Configuration Software 24