User guide

k
Power connector — Connect the 2-pole, 3.5 mm captive screw connector from the
12 VDC, 1.0 A power supply (not provided) to the power supply socket on the rear
panel. Ensure the connections have the correct polarity as shown in figure 10.
NOTES:
Extron recommends using the Power over Ethernet power supply.
The 12VDC, 1.0 A power supply should only be used for setup or
troubleshooting.
If both power supplies are connected to the TLP 710TV, the PoE power
supply takes precedence.
Power Receptacle
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
3/16"
(5 mm) Max.
Figure 10. Power Supply Connection
ATTENTION: See the Attention on page 7 for important information about
power supplies.
NOTE: See the notes on page 7 for important information about wiring captive
screw connectors.
l
MTP signal adjustments — Three MTP signal adjustments are available for S-video
luminance gain (VID/Y), S-video chrominance gain (C), and sharpness (S). For
composite video signals, the gain is controlled by the VID/Y adjustment. Insert a small
Phillips head screwdriver into the recess and turn clockwise to increase adjustment or
counterclockwise to decrease.
m
VESA mounting holes — Four holes are arranged in a pattern that is in accordance
with the VESA FDMI standard, type D 75 mm (see Figure 9). See page 46 for more
information about mounting the TLP 710TV with the Extron LPVM-1.
TLP 710MV and TLP 710TV • Panel Features 11