User guide

LAN Connector
MTP Connector
Zip-tie Holder
Zip-tie Holder
Cable Runway
Figure 11. Connecting and Securing Cables
n
Power connector — connect the two pole, 3.5 mm captive screw connector from
the 12 VDC, 1.0 A power supply (not provided) to the power supply socket on the
rear panel. Ensure the connections have the correct polarity as shown below.
NOTES: Extron recommends using the Power over Ethernet power supply.
The 12 VDC, 1.0 A power supply should be used only for setup or
troubleshooting.
If both power supplies are connected to the TLP 1000TV, the PoE power
supply takes precedence.
Power Receptacle
DC Power Cord
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
3/16"
(5 mm) Max.
Figure 12. Power Supply Connection
CAUTION: See the cautions on page 8 for important information about power
supplies.
NOTE: See the notes on page 8 for important information about wiring captive
screw connectors.
TLP 1000MV and TLP 1000TV • Panel Features 12