 Power connector — connect the two pole, 3.5 mm captive screw connector from 
the 12 VDC, 1.0 A power supply (not provided) to the power supply socket on the 
rear panel. Ensure the connections have the correct polarity as shown below.
NOTES: • Extron recommends using the Power over Ethernet power supply. 
This 12 VDC, 1.0 A power supply should be used only for setup or 
troubleshooting.
  • If both power supplies are connected to the TLP 1000MV, the PoE power 
supply takes precedence.
Power Receptacle
DC Power Cord 
Captive Screw Connector
AC Power Cord
Ground 
+12 VDC 
External 
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
3/16"
(5 mm) Max.
Figure 7.  Power Supply Connection
CAUTIONS:  •  Always use a power supply supplied by or specified by Extron. Use 
of an unauthorized power supply voids all regulatory compliance 
certification and may cause damage to the supply and the end 
product.
  • Unless otherwise stated, the AC/DC adapters are not suitable for 
use in air handling spaces or in wall cavities. The power supply is 
to be located within the same vicinity as the Extron AV processing 
equipment in an ordinary location, Pollution Degree 2, secured to 
the equipment rack within the dedicated closet, podium or desk.
  • The installation must always be in accordance with the applicable 
provisions of National Electrical Code ANSI/NFPA 70, article 75 and 
the Canadian Electrical Code part 1, section 16. The power supply 
shall not be permanently fixed to building structure or similar 
structure.
NOTES: • The length of the exposed wires in the stripping process is critical. The 
ideal length is 3/16 inches (5 mm). Any longer and the exposed wires 
may touch, causing a short circuit between them. Any shorter and the 
wires can be easily pulled out even if tightly fastened by the captive 
screws.
  • Do not tin the wires. Tinned wire does not hold its shape and can 
become loose over time.