User Guide Manual
5-37System 5 IP • SIS
™
Programming and Control
PRELIMINARY
Command/response table for special function SIS commands, continued
Command ASCII Command Response
X?
values
(host to Syst. 5IP) (switcher to host) and additional descriptions
Each control module (IRCM, ACM, RCM) has 20 memory blocks reserved for it, no matter how many buttons are
physically present on the module:
• module 1: blocks 26-45
• module 2: blocks 46-65
• module 3: blocks 66-85
• module 4: blocks 86-105
Memory block numbers are sequential from left to right, top row to bottom row, as shown below.
SCREEN POSITION
DOWN UPSTOP
DVD & VCR CONTROL
PLAY NEXT/FWD PAUSE STOP
TUNER
Tx
PREV/REW
ENTER
TITLE MENU
TV/VCR
DVD VCR
DVD & VCR CONTROL
PLAY NEXT/FWD PAUSE STOP
TUNER
Tx
PREV/REW
ENTER
TITLE MENU
TV/VCR
DVD VCR
Button/Switch Memory Block Numbering for Control Modules (IRCMs, ACMs, RCMs)
Memory Block
Numbering Scheme for
Any Type of Module
(Example is for Control Module 1)
Memory Block Numbering Examples
DVD Half
(module 1)
IRCM-DV+ with DIP switch set for addresses 0 and 1 (modules 1 and 2)
RCM-SC with DIP switch set for address 2 (module 3)
VCR Half
(module 2)
26 27 28 29 30
35
30
40
45
31 35343332
36 40393837
41 45444342
31 353332
36 39
29
37
41 45444342
66 7068
51 555352
56 59
49
57
61 65646362
Module 3 has
memory blocks
66 to 85.
Module
1 has
memory
blocks
26 to 45.
Module
2 has
memory
blocks
46 to 65.
Button press repeating
Set the button press repeat rate
24
X?
*
Y?
*45 # RptRate*
X?
*
Y?
This command sets the switcher
to repeatedly send commands
associated with button
X?
at the
interval specified by
Y?
.
X?
= the number of the memory
block for the button/switch (1 -
127) to set the repeat rate for.
See the diagrams above.
Y?
= the repeat interval
(0 - 65535 ms in 20 ms steps).
Read/display the button press repeat rate
45 #
X?
*
Y?
Clear the button repeat rate 0*0*45 # RptRate*000*00000 Turn off continuous repeat
mode.