User Guide Manual
5-19System 5 IP • SIS
™
Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Request status of attached hardware 32I 32I P1##•P2##•K1##•K2##•K3##•K4##•S##
Show the presence/absence and type of
connected devices.
P1 = SCP 150 #1, address 0
P2 = SCP 150 #2, address 1
K1 = control module #1, address 0
K2 = control module #2, address 1
K3 = control module #3, address 2
K4 = control module #4, address 3
S = MPS 112/MPS 112CS slave
switcher.
For ##:
00 = not present
01 = present or IRCM-VCR or SCP 150 or MPS 112
02 = IRCM-DVD or SCP 226 or MPS 112 CS
03 = IRCM DVD+ or SCP 104
04 = ACM-Level
05 = ACM-Tone
06 = RCM-SC
07 = RCM-SCLT
08 = IRCM-Tape
09 = CM-5BB
10 = CM-20BB
11 = IRCM-DV+
12 = CM-9BLB
13 = CM-3BLB
99 = a device is present, but
unrecognized.
Example: 32I 32I P101 P200 K102 K201 K308 K407 S00
This example includes one SCP 150 (P101),
an IRCM-DVD (K102), an IRCM-VCR
(K201), an IRCM-Tape (K308), and an
RCM-SCLT (K407). There is no slaved
switcher.
IP setup commands
Set the unit name
24
Esc
X12
CN W
X12
CN
|
Ipn•
X12
Change the switcher’s name to one of your
choosing (
X12
), such as
“LectureHallSwitcher” or “boardroomA-
Syst5IP”. The name consists of up to 24
alphanumeric characters (and the minus
sign). The first character must be a letter,
the last character cannot be a minus sign
(hyphen). Case does not matter.
Set unit name to factory default
24
Esc
•CN W%20CN
|
Ipn•
X49
X49
= the name the switcher was shipped
with: SYSTEM5IP-##-##-##, a combination
of the model name and the last 3 pairs of
hex numbers in the switcher’s MAC address
(e.g., SYSTEM5IP-00-02-3D)
Read the unit name
Esc
CN WCN
|
X12
or
X49
X12
is the switcher’s current unit name.
X49
is the switcher’s factory default name.
Set time/date
24
Esc
X13
CT W
X13
CT
|
Ipt•
X13
X13
= Local date and time format.
The set format is MM/DD/YY-HH:MM:SS.
Example: 11/18/03-10:54:00.