User Guide Manual

SIS
Programming and Control, cont’d
System 5 IP • SIS
Programming and Control5-16
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)
Configure an IR/Serial Out port
24
Esc
X215
*
X210
IC W
X215
%2A
X210
IC
|
Irc
X215
*
X210
This command sets IR/Serial Output port
number
X215
(1 = port A, 2 = port B,
3 = port C, 4 = port D) for either
IR (
X210
= 0) or RS-232 (
X210
= 1) output.
View an IR/Serial port’s config.
Esc
X215
IC W
X215
IC
|
X210
Example:
Esc
3 IC W3 IC
|
01 View IR/Serial Output port C’s
configuration, which is RS-232 (01) in this
example.
Ethernet data port configuration and use
Set the timeout period for the LAN (Ethernet) port’s current connection
24
Esc
0*
X69
TC W0%2A
X69
TC
|
Pti 0*
X69
Set the time to wait (
X69
= waiting time in
tens of ms) to receive the next character
before terminating the Ethernet connection.
The response includes leading zeros.
X69
= 1-65000 steps at 10 seconds per step,
default = 30 = 300 seconds.
This timeout period applies only when the switcher is connected to a PC via Ethernet. When it is connected to a PC via RS-232, only the global timeout commands apply.
View the current connection timeout period
Esc
0TC W 0TC
|
X69
Set the LAN port’s global timeout period
24
Esc
1*
X69
TC W1%2A
X69
TC
|
Pti 1*
X69
Set the time to wait (
X69
= waiting time in
tens of ms) to receive the next character
before terminating the Ethernet connection.
View the LAN port’s global timeout period
Esc
1TC W 1TC
|
X69
Digital input data port (power sense port, right 3 pins of the projector/display control port)
Set I/O mode
24
1*
X40
[ 1 %2A
X40
%5B Iom 1*
X40
X40
= I/O mode
0 = input
8 = power sensor (triggers when the input
pulse starts/stops).
View I/O mode 1[ 1 %5B
X40
View I/O state 1] 1 %5D
X43
X43
= I/O state
0 = off
1 = on
An input voltage of less than 0.6 VDC is considered as logic low, and an input voltage of greater than 0.7 VDC is considered to be logic high. These thresholds are not
adjustable.