User Guide Manual
SIS
™
Programming and Control, cont’d
System 5 IP • SIS
™
Programming and Control5-10
PRELIMINARY
Audio treble adjustment (global: applies to all inputs)
Set the treble level
X7
>
X7
%3E Trb
X7
Set the global treble level.
X7
= 0 to 10,
-10 dB to +10 dB in 2 dB steps (0 = -10 dB,
1 = -8 dB, 2 = -6 dB,... 10 = +10 dB).
Example: 2> 2%3E Trb02
Example: set treble to -6 dB.
Increment an input’s treble level + > %2B%3E Trb
X7
Increase the treble by 2 dB.
Decrement an input’s treble level – > %2D%3E Trb
X7
Decrease the treble by 2 dB.
View the treble level > %3E
X7
Show the current treble level.
Audio bass adjustment (global: applies to all inputs)
Set the bass level
X7
<
X7
%3C Bas
X7
Set the global bass level.
X7
= 0 to 10, -10 dB
to +10 dB in 2 dB steps (0 = -10 dB,
1 = -8 dB, 2 = -6 dB,... 10 = +10 dB).
Increment the bass level + < %2B%3C Bas
X7
Increase the bass by 2 dB.
Decrement the bass level – < %2D%3C Bas
X7
Decrease the bass by 2 dB.
View the bass level < %3C
X7
Show the current bass level.
Audio mute (overall: amp and preamp)
Mute on 1Z 1Z Amt1 Mute all (Lineout/fixed, Preamp/variable,
& amplified) audio outputs. This is not the
same as selecting input 0.
Mute off 0Z 0Z Amt0
Unmute all audio outputs.
View the audio mute status Z Z
X5
Show the status of audio mute.
X5
= 0 (off/disable) or 1 (on/enable).
The 1Z mute command is not the same as selecting input 0.
Audio status for the active input
These commands allow you to view (or program a control system to monitor) the on/off status of the Signal, Normal, and Clip indicators (the equivalent of viewing the front
panel Min, Mid, Max Volume LEDs) between adjustments to the audio input levels. For details on making these adjustments via the front panel controls, see chapter three.
View Signal, Normal, & Clip status S or 0S S or 0S Sig
X5
•Norm
X5
•Clp
X5
X5
= 0 (off) or 1 (on).
View Signal (Min) status 1S 1S
X5
Signal detection threshold:
0 = off (Signal level is too low to detect.)
1 = on (A signal of at least -20 dBV
[-18 dBu] is present.)
View Normal (Mid) status 2S 2S
X5
Normal range:
0 = off (Input level is too low.)
1 = on (Input is in the right range.)
Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response Additional description
(host to switcher) (host to switcher) (switcher to host)