2-3System 5 IP Switchers • Installation: Labeling, Mounting, Cabling
PRELIMINARY
Mounting the System 5 IP
Rack mount the switcher, if desired, using the included rack mounting kit
(part #70-077-03), which is factory installed. Otherwise, affix the four rubber feet
(included) to the corners of the bottom of the switcher for use on a tabletop.
Rack mounting
For rack mounting, do not install the rubber feet. The rack mounting brackets are
attached to the switcher at the factory. Fasten the switcher to the rack using the
supplied machine screws.
CAUTION
The System 5 IP switchers do not contain cooling fans. Make sure there
will be adequate air circulation around the unit once it is installed. To
provide adequate air circulation and prevent overheating, Extron
recommends allowing one rack unit of space (1.75"/4.5 cm) above and
below the switcher.