User Guide Manual
SMX System MultiMatrix Switcher • SIS Configuration and Control 39
X1^
= HDCP compliance 0 = no source connected 
1 = source is HDCP compliant 
2 = source is not HDCP compliant
X1&
= Executive mode 0 = enable (basic and admin) 
1 = disabled front panel 
2 = enabled (basic only)
X1*
= Reclocker rates for SDI/HD-SDI 
boards
00 = auto detect (default) 
01 = bypass reclocker
X1(
= Signal status 0 = no signal at the input 
1 = signal at the input (H) 
2 = signal at the input (V) 
3 = signal at the input (HV/receive link 
presence for fiber boards)
X2)
= Output connection status 0 = no active connection on A or B 
1 = first (A) port connected and second 
 (B) port not connected 
2 = first (A) port not connected and 
 second (B) port connected 
3 = active connection on both A and B
X2!
= Version number x.xx.xxxx (the first 3 numbers is the 
version number and the last 4 is the 
build number)
X2@
= Plane addresses 00 – 15 = for 16 planes 
90 – 99 = for virtual planes (10 planes)
X2$
= Voltage Positive or negative voltage magnitude
X2%
= Temperature In Degrees Fahrenheit
X2^
= Fan speed In RPM
X2(
= Create virtual plane address 90 – 99 = 10 planes
X3)
= Slot number 1 – 4 for 2U units 
1 – 6 for 3U units 
1 – 8 for 4U units 
1 – 10 for 5U units 
00 = e-mail F & P 
1 – 10 = e-mail I