User’s Manual RGB 472xi , 474xi , 478xi , and 478 Mxi www.extron.com Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Quick Start Guide — RGB 470xi xi Series To install and set up an RGB 470xi series interface, follow these steps: Step 1 Turn all of the equipment off and disconnect from the power source. Step 2 If applicable, prepare the site (refer to the appropriate Installation Guide for information on your specific situation). Step 3 Attach the input cables to the front of the interface, as required.
Quick Start Guide — RGB 470xi xi Series, cont’d Quick Start Guide — RGB 470xi xi Series, cont’d Step 5 Step 6 Closed / On Set the rear panel DIP switches. 1 2 3 4 5 6 7 8 Connect power cords and turn on all equipment. Open / Off The default for all DIP switches is Off (down). 1 — Sync on green On — The interface outputs sync on green. Off — The interface outputs separate horizontal and vertical sync for RGBHV. Step 7 The picture should now appear, and sound should be audible.
Quick Start Guide — RGB 470xi xi Series, cont’d Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About this Manual ................................................................ 1-2 xi Series of Interfaces .................. 1-2 About the RGB 470xi Features ...................................................................................... 1-2 Chapter 2 • Operation ................................................................
Table of Contents, cont’d RGB 470xi xi Series This page intentionally left blank 1 Chapter One Introduction About this Manual About the RGB 470xi Series of Interfaces Features ii xi Series • Table of Contents RGB 470xi
Introduction About this Manual This manual contains information about the Extron RGB 470xi series of universal wall, furniture and floorbox mountable interfaces, and on how to configure and operate them. Unless otherwise noted, “interface” will be used to refer to all models interchangeably. For information on installing the wall box-mountable versions of these interfaces, refer to one of the available installation guides. For wall or furniture mount installations (and EC versions), refer to #68-636-03.
Installation UL Requirements 5 4 The following Underwriters Laboratories (UL) requirements pertain to the installation of the RGB 470xi series of interfaces into a wall or furniture. 7 6 INPUT SELECT 1 MIN/MAX 2 1 1. These units are not to be connected to a centralized DC power source or used beyond their rated voltage range. 2 2. These units must be installed in UL listed junction boxes. 3 3. These units must be installed with conduit in accordance with the National Electrical Code. H.
Installation, cont’d Tip (L) Sleeve (GND) 13 xi Network connectors (RGB 474xi xi) — Connect a computer to this RJ-45 female connector for pass-through to a network. 14 Opening for Architectural Adapter Plates — The RGB 478xi can accept up to four optional standard architectural adapter plates (AAPs) attached here. The RGB 478 Mxi (not pictured) can accept up to four optional mini architectural adapter plates (MAAPs) attached here. The adapter plates come with a variety of audio/video connectors.
Installation, cont’d 1 CAUTION Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative (-) terminal will damage the audio output circuits. Unbalanced Output 5 — Negative sync — This switch controls sync polarity. R+ R- Audio Mono See Caution Tip Ring Sleeve (s) Tip Ring L+ L- R+ R- Sleeve (s) Tip On — The interface outputs serration pulses in the vertical sync interval. Off — The interface does not output serration pulses.
Installation, cont’d may be overcompensated. If the edges of the image seem to exceed their boundaries, or if thin lines and sharp edges look thick and fuzzy, try changing the gain/ peaking setting. Adjust the gain before installing the interface into a wall or furniture, as the gain switch will be inaccessible after installation. Power connector — Connect a 9VDC to 24VDC power supply to this 3.5 mm, 2-pole one-piece captive Power screw connector. Wire the connector as + or – – or + shown here.
Installation, cont’d Mounting the optional AAP or MAAP devices Application Examples The interface and any optional architectural adapter plates (standard or mini) must be cabled before the interface is installed in a wall or furniture. The screws needed for installing the optional standard AAP devices are built into its front panel, and hex screws are provided with the MAAP devices, so no additional screws will be needed. 1.
Installation, cont’d RGB 470xi xi Series This page intentionally left blank A Appendix A Specifications and Parts Specifications Included Parts Accessories Cables Optional Adapter Plates 2-12 xi Series • Operation RGB 470xi
Specifications and Parts These specifications apply to all models unless otherwise noted. Specifications Video Routing .......................................... 2 x 1 router Gain ............................................... Unity (0.7V), 15% with 3dB peaking (0.8V), 30% with 6dB peaking (0.9V) Bandwidth .................................... 300 MHz (-3dB) Video input and loop through Number/signal type ................... 2 analog RGBHV, RGBS, RGsB Connectors ....................................
Specifications and Parts, cont’d Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non condensing Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non condensing Rack mount ................................... No RGB 472/474/478xi SC-AFM models Steel City AFM floor box mountable RGB 472xi FSR models .... FSR floor box mountable All other models .............. Wall or furniture mountable Enclosure type ..............................
Specifications and Parts, cont’d Included Parts These items are included in each order for an RGB 470xi series interface: Included parts RGB 472xi (grey, black, white) Part number 60-515-01, -02, -03 or RGB 472xi EC (white faceplates) 60-515-10 or RGB 474xi (grey, black, white) 60-519-01, -02, -03 or RGB 478xi (grey, white, black) 60-521-01, -02, -03 or RGB 478xi EC (white) or RGB 478 Mxi (black and white) & 2-gang mud ring kit 70-086-01, -11, -21 or 3-gang mud ring kit 70-086-02, -12,
Specifications and Parts, cont’d Optional Adapter Plates A variety of optional adapter plates for pass-through connections may be ordered for the RGB 478xi and RGB 478 Mxi interfaces. The RGB 478xi can have up to 4 adapter plates installed, and the RGB 478 Mxi can have up to 4 mini adapter plates installed.