User’s Manual RGB 400 Series Mountable Interfaces Extron Electronics, USA 1230 South Lewis Street, Anaheim, CA 92805 800.633.9876 714.491.1500 FAX 714.491.1517 USA Extron Electronics, Europe Beeldschermweg 6C, 3821 AH Amersfoort +31.33.453.4040 FAX +31.33.453.4050 The Netherlands Extron Electronics, Asia 135 Joo Seng Rd. #04-01, PM Industrial Bldg. +65.383.4400 FAX +65.383.4664 Singapore 368363 Extron Electronics Information ExtronWEB™: www.extron.com ExtronFAX™: 714.491.
Precautions Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock. Caution Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About this Manual ................................................................ 1-2 About the RGB 400 Series Interfaces .......................... 1-2 Features ...................................................................................... 1-2 RGB 400 Series features ......................................................... 1-2 Additional RGB 404 features ......................................
Table of Contents, cont’d Appendix C • Dimensions ........................................................ C-1 RGB RGB RGB RGB 404 406 408 408 Panel Panel Panel Panel Dimensions ............................................... C-2 Dimensions ............................................... C-5 Dimensions ............................................... C-6 Dimension Details ................................. C-7 Appendix D • Accessories and Part Numbers .......... D-1 Interfaces and Included Parts .........
Introduction, cont’d Introduction About this Manual This manual contains information about the RGB 400 Series interfaces and on how to operate and configure them. RGB 400 Series About The RGB 400 Series Interfaces The RGB 400 Series are 300 MHz (-3dB) bandwidth, analog computer-video interfaces that can be mounted in walls or furniture. The RGB 406 is two-gang wall plate size, the RGB 404 is three-gang size, and the RGB 408 is four-gang size. All are available with black, white, or gray panels.
Installation and Operation, cont’d Installation and Operation Installation Overview To install and set up an RGB 400 Series interface, follow these basic steps: 2-2 1 Determine the installation location. 2 Prepare the site for installation. Use the supplied template to mark the rough-in cutout, then cut out the wallboard or wood. 3 Set the DIP (dual in-line package) switches and jumpers. These items will be inaccessible after installation.
Installation and Operation, cont’d Preparing the installation site and installing the wall box Actual-size rough-in templates for each model are provided in Appendix B. If needed, make a 100% size photocopy of the appropriate template to use for installation. Compare the photocopy with the faceplate and wall box to make sure the photocopy size is the same as the equipment.
Installation and Operation, cont’d Front and rear panel (circuit board) features 18 17 Yellow 18 17 16 19 Red Black Green J11 RGB 404 front and rear features J12 J9 3 4 5 CH1R 6 8 9 10 CH1R 1 2 1 = +5V 20 mA max. 2 = –5V 20 mA max. 3 = Ground PC H. SHIFT RGB 404 8 7 6 5 9 .8V .9V 3 2 1 J13 1. ON = Remove serration pulses. 2. ON = Digital display sync. SW1 NETWORK Extron J8 J10 J13 ON AUTO POWER A U D I O 7 75 Ohm SW1 ON 2 R CH1L L 1 S-VIDEO 33-323-01 L 3.
Installation and Operation, cont’d RGB 406 front and rear features 14 9 SW1 DIP switches — 1. On = Removes serration pulses. 2. On = Enables Digital Display Sync Processing (DDSP). J11 J12 J9 10 J10 blue gain/peaking jumper — Settings are shown on the label located below the circuit board. 11 J9 green gain/peaking jumper 12 J8 red gain/peaking jumper 13 Circuit board — Only key components are shown here. 14 Twisted-pair wires — Splice these wires to a 12 to 24VAC or VDC power source.
Installation and Operation, cont’d RGB 408 front and rear features 15 J11 J12 J9 HIGH Z INPUT 1 2 SW1 J8 J10 ON 75 Ohm AUTO POWER AUDIO J13 H. SHIFT 1 = +5V 20 mA max. 2 = –5V 20 mA max. 3 = Ground Extron 2 3 4 5 6 1 Auto power LED — If this LED is on, power and video sync pulses are present. If no sync is present, power and this LED turn off. 2 H. Shift (horizontal shift) control — This controls horizontal centering.
Installation and Operation, cont’d Setting DIP switches and jumpers DIP switches and jumpers must be set and tested before the interface is secured into the wall box, wall or furniture. DIP switches ON 1 2 DIP switch module SW1 contains two DIP switches (SW1-1 and SW1-2). The module is located on the circuit board on the back of the interface, as shown on pages 2-6, SW1 2-7, 2-9, 2-11 and 2-13. In these illustrations, the On position is to the left.
Installation and Operation, cont’d Cabling RCA connectors Adapter Plate INP UT AU TO HIG HZ PO WER 75 H. SH IFT For composite video, solder the center conductor of a coaxial cable to the central solder cup of the RCA connector. Solder the cable’s shield to the grounded grounding tab. See the leftmost and center illustrations below.
Installation and Operation, cont’d If shielded twisted-pair wires are used for audio output for the RGB 404, RGB 406 or RGB 408, the shields should be connected to either pin 3 (RGB 406/408) or pins 3 and 8 (RGB 404) of the audio output captive screw connector. Twist the wires from the braided shield together to form a multi-strand wire, then insert it into the receptacle side of the captive screw connector. See the “Wiring audio output captive screw connectors” illustration on the next page.
Installation and Operation, cont’d output captive screw connector. See “Connecting shields” earlier in this chapter for details. Connecting audio cables — RGB 406, RGB 408 Using installation cable Extron’s Install Plenum bulk cable (shown here) is ideal for mountable interfaces such as the RGB 400 Series models. Six Mini, High-resolution Coaxial Conductors Each RGB 406 or RGB 408 accepts an unbalanced audio input from a front panel 3.
Installation and Operation, cont’d 3. Check the cabling and the audio connector wiring, and make adjustments as needed. 4. Verify that the High Z/75 Ohm video input termination toggle switch on the front panel has been set correctly. 5. For digital display devices (including LCD, DLP and plasma devices), try turning DDSP on or off using the rear panel SW1-2 DIP switch. 6. Call Extron’s customer support hotline if needed. If the image does not display correctly 1.
Installation and Operation, cont’d 4. 5. For all models, carefully place the interface through the opening in the wall or furniture and into the wall box (if one is used). Take care not to damage the cables. Mount the interface faceplate to the wall box with the provided machine screws (as shown below), or attach the interface directly to the furniture with wood or metal screws. Application diagrams Below are examples of typical system installations that incorporate RGB 400 series interfaces.
Installation and Operation, cont’d RGB 400 Series A Appendix A Specifications Specifications 2-24 RGB 400 Series • Installation and Operation
Specifications, cont’d Specifications These specifications apply to all models unless otherwise noted. Video input Number/type ............................... 1 analog RGBHV, RGBS, RGsB Connectors .................................... 1 9-pin male D connector for MBC/LBC cable or buffer Nominal level(s) .......................... Analog ....... 0.3V to 1.45V p-p Impedance .................................... 75 ohms or Hi Z, switchable (set to 75 ohms if no local monitor is connected) Horizontal frequency .
Specifications, cont’d Impedance .................................... 50 ohms, unbalanced, 100 ohms balanced Gain error ...................................... ±0.1dB channel to channel Drive (600 ohm) ........................... +14dBu, balanced at stated %THD+N General Approvals ..................................... UL, CE, FCC Class A MTBF ............................................. 30,000 hours Warranty .......................................
Specifications, cont’d RGB 400 Series B Appendix B Templates RGB 406 Cut-out Template RGB 404 Cut-out Template RGB 408 Cut-out Template A-6 RGB 400 Series • Specifications
Templates, cont’d Templates All the templates in this section are actual size. Also, they all include the recommended 0.1” (0.25 cm) clearance on all sides of the electrical wall box to allow room for the raised areas surrounding the knockouts. RGB 404 Cut-out Template Use this template for cutting a hole in a wall or furniture for the 3-gang size electrical box for an RGB 404. The dashed line in each template indicates the cut-out area for installing a wall box.
B-4 RGB 400 Series • Templates The dashed line indicates the cut-out area (3.95"H x 7.58"W) for installing the electrical wall box. Use this template for cutting a hole in a wall or furniture for the electrical box and pass-through connections for the 4-gang size RGB 408. RGB 408 Cut-out Template To install the interface without a wall box, use the cut-out area (3.00"H) indicated by the dotted line. The light gray area represents the layout of the electrical box (3.75"H x 7.
C-2 RGB 400 Series • Dimensions ø.125 THRU ø.230 THRU DETAIL A H. SHIFT ø.230 THRU ø.125 THRU DETAIL A E B ø.213 A U D I O Extron H. SHIFT AUTO POWER E E C PC L VIDEO C AUDIO R 75 Ohm HIGH Z RGB 404 NETWORK C S- VIDEO 2 REQ'D ø.085 THRU (2 PLACES) ø.156 THRU C'SINK ø.290 x 82˚ (4 PLACES) ø.236 THRU C'BORE ø.400 x .060 DEEP DETAIL C STANDOFFS: 2 REQ'D (VIEWED FROM BACK SIDE) DETAIL C DETAIL B SCALE: 2/1 DETAIL A ø.120 THRU, WITH ø.250 C'BORE ON BOTH SIDES, .
.225 .190 DETAIL B ø.201 DETAIL A RGB 400 Series • Dimensions DETAIL C H. SHIFT AUTO POWER Extron .449 4– R .132 0.000 .06 ø.120 THRU, WITH ø.250 C'BORE ON BOTH SIDES, .040 DEPTH ON THE NEAR SIDE, AND .020 DEPTH ON THE FAR SIDE. (2 PLCS.) .403 0.000 0.609 ø 0.230 THRU 1.395 1.140 1.055 1.050 2.280 2.175 ø 0.125 THRU 0.744 DETAIL A 1.154 3.450 AUDIO INPUT 1.375 2.750 1.444 3.891 ø.400 75 Ohm HIGH Z DETAIL B 2.740 3.520 3.844 1.370 1.760 3.000 DETAIL D 1.500 0.
Dimensions, cont’d RGB 400 Series D Appendix D Accessories and Part Numbers Interfaces and Included Parts Accessories and Connectors Cables Optional Adapter Plates C-6 RGB 400 Series • Dimensions
Part Numbers Accessories, cont’d Part Numbersand and Accessories Interfaces and Included Parts Cables This section lists the interfaces and the main parts that are shipped with each model. All models include: • this manual, part number 68-364-01, • one standard cable clamp with two machine screws, and • four 3/8 inch, flathead screws (for attaching the faceplate). Interfaces and included parts Part number RGB 404G (gray faceplate) RGB 404B (black faceplate) RGB 404W (white faceplate) 0.
D-4 RGB 400 Series • Part Numbers and Accessories -21 -11 -01 70-106 solder cups 1 1 contact closure switch/LED show-me and 3.5mm stereo mini jack contact closure switch and 3.5mm mini stereo jack -21 -11 -01 70-105 solder cups 1 1 3.5mm, 5 pole captive screw terminal 3.
D-6 Plate size 2 1 Adapter plate description 1 S-video female and 3 RCA female 1 BNC female and 1 3.5mm mini stereo jack BNC female and 3 solder cups 4-pin mini DIN female and RCA female 4-pin mini DIN female and RCA female BNC female and 3.
Part Numbers and Accessories, cont’d D-8 RGB 400 Series • Part Numbers and Accessories