User Manual Interfaces RGB 580xi Architectural Remote Interface with Audio and ADSP™ 68-536-01 Rev.
Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Warning Power sources • This equipment should be operated only from the power source indicated on the product.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.
Contents Introduction............................................................ 1 About this Guide................................................. 1 About the RGB 580xi Interface............................. 1 Features............................................................... 1 Installation and Operation.................................. 3 Installation Overview............................................ 3 Application Diagrams...........................................
Introduction This section gives an overview of the user guide and describes the Extron® RGB 580xi and its features. Topics that are covered include: • About this Guide • About the RGB 580xi Interface • Features About this Guide This guide describes the function, installation, configuration, and operation of the Extron RGB 580xi interface.
Remote contact closure — A contact closure signal can be sent to the interface from the remote AAP. RS-232 control — A set of instructions are available via the Extron control software for Windows®, or a control system.
Installation and Operation This section describes the installation and the operation of the RGB 580xi.
7. The picture should appear, and sound should be audible. If not, ensure that all devices are plugged in and receiving power. Check the cabling and make adjustments as needed. 8. While watching the display, adjust the video level and peaking by using the rotary Level and Peaking controls. See “Front Panel Adjustments”.
RGB 580xi CCSI AAP H .S H IF T S INP E U L T E C T Audio Projector INP SEL UT ECT To VGA RGB To Audio SELEINPUT CT 580 xi CCI AAP Network WIDTH V-SYNC SYNC NEG SYNC COMP SOG SERR DDSP 580 UT OUTP VIDEO TS INPU OG ROL E C CONT B G PEAKIN xi RGB LEVEL D A ANAL O AUDI LAN/WAN Network/ Internet INPUTS AUDIO ANALOG CONTROL A B C D E SOG SERR DDSP VIDEO OUTPUT LEVEL V-SYNC WIDTH NEG SYNC COMP SYNC PEAKING RGB 580xi RGB 580xi Figure 3.
RGB 580xi Front Panel Features and Cabling Front Panel INPUTS AUDIO ANALOG CONTROL A B C D E SOG SERR DDSP V-SYNC WIDTH NEG SYNC COMP SYNC VIDEO OUTPUT LEVEL PEAKING RGB 580xi 1 2 3 4 5 6 7 Figure 4. RGB 580xi Front Panel a Power/signal LED — This LED lights green to indicate that the RGB 580xi is receiving power. b Audio input connector — Plug a 3.5 mm stereo plug into this jack for unbalanced audio input. Wire the male plug as shown below. Tip (L) Ring (R) Sleeve ( ) Figure 5.
5-pin Contact Closure Captive Screw Con_lateral.
3 — SOG (sync on green) On — The interface outputs sync on green. Off — The interface outputs separate horizontal and vertical sync (on the H and V connectors) for RGBHV. 4 — V-Sync Width (vertical sync pulse width) — For some digital display devices, if no picture appears, the picture cuts in and out, or the picture is scrambled, try adjusting the output vertical sync pulse width or switching from ADSP to DDSP. On — The vertical sync pulse is narrow. Off — The vertical sync pulse is wide.
Rear Panel Features and Cabling 100-240 0.5A MAX. OUTPUTS R H B G V AUDIO RS-232 Tx Rx 50/60 Hz 1 4 3 2 Figure 6. RGB 580xi Rear Panel a AC power connector — Connect a standard IEC AC power cord here for power input (100 VAC to 240 VAC, 50/60 Hz) to the internal power supply.
NOTE: If the displayed image is too bright or too dark, try changing the level setting. If the edges of the displayed image seem to exceed their boundaries, or if thin lines and sharp edges look thick and fuzzy, try changing the peaking setting. See the illustration below. TH WID YNC C V-S SYN C NEG SYN MP CO G SO R SER SP DD TS INPU OG NT COB C L ROE UT TPING AK O OU PE L VIDE VE LE D A AL AN B RG i 0x 58 Peaking O DI AU Level 1.
AAP Device Features 3 RGB 580xi AAP AUDIO IN 4 3 SHIFT AUDIO IN COMPUTER IN COMPUTER IN RGB 580xi RGB 580xi 1 2 RGB 580xi S AAP 1 2 3 4 SHIFT SELECT RGB 580xi SI AAP AUDIO IN COMPUTER IN RGB 580xi 1 5 2 Figure 7. RGB 580xi AAP Front Panels a Power/signal LED — This LED lights оо red to indicate that the AAP device is receiving power. оо green to indicate that an active sync signal is present at the input and that the AAP device is receiving power.
Cabling the AAP Device Rear Connectors Various Extron AAP devices for the RGB 580xi may come with several rear connectors that require cabling. NOTE: Although the VGA and control cable/LED assembly comes prewired to the captive screw connectors, any subsequent cable assembly replacement will require the following cabling instructions. To cable the captive screw connectors, refer to the following diagrams and position the wires according to the view angle of the captive screws.
Cable Cubby AAP Device Features 1 HORIZONTAL SHIFT 2 1 HORIZONTAL SHIFT 2 INPUT SELECT RGB 580xi CCS AAP 3 RGB 580xi CCSI AAP Figure 9. RGB 580xi AAP Front Panels Installation of the RGB 580xi CC AAP devices in a Cable Cubby allows the VGA and audio cable connectors of the CC AAP device to be accessible, as shown in the following diagram. RGB 580xi CCSI AAP H .
c Input select button — Pressing this button results in contact closure between pins A and B of the contact closure control connector on the front panel of the RGB 580xi. Cabling the Cable Cubby AAP Devices Various Extron CC AAP devices for the RGB 580xi come with rear panel connectors that may require cabling. NOTE: Although the control cable/LED cable assembly comes prewired to the captive screw connectors, any subsequent connector replacement will require the following cabling instructions.
Troubleshooting Turn on the input devices (computer, audio device) and output device(s) (projector, monitors, speakers). The image should now appear on the screen, and sound should be audible. If the Image Does Not Appear or There is No Sound 1. Ensure that all devices are plugged in. 2. Make sure that each device is receiving power. The front panel LED lights green if the interface is receiving power. 3. Check the cabling and the audio connector wiring and grounding, and make adjustments as needed. 4.
Remote Control This section discusses how to connect and configure the RGB 580xi. Topics that are covered, include: • RS-232 Programmer Guide • Windows®-Based Program Control • Contact Closure Remote Control RS-232 Programmer Guide The interface can be remotely controlled via a host computer attached to the 3-pole captive screw RS-232 connector on the rear panel.
RECONFIG When the RGB video input of the remote interface is disconnected or the horizontal shift control (H. shift) is adjusted from the AAP device (RGB 580xi S/CCS AAP and RGB 580xi SI/CCSI AAP), the interface sends the reconfiguration message. No response is required from the RS-232 host, but the host may request a new status listing via the request information command (I/i). See the command/response table in this chapter for details.
Symbol Definitions ] = CR/LF (carriage return/line feed, hex 0D 0A) • = Space X! = Shift control range (-63 to +63) X@ = Controller firmware version (listed to two decimal places: x.xx) X# = Frequency in Hz or kHz (listed as xxx.xx) Command ASCII (host to interface) Response Additional (interface to host) Description Chn] NOTE: Contact closure has been detected across pins 1 and 2.
Windows®-Based Program Control The included graphical control software for Windows offers another way to control the interface via RS-232 in addition to the Simple Instruction Set commands listed on the previous page. The control software is compatible with Windows 2000, Windows XP, and later versions of Windows. Upgrades to the program can be downloaded from the Extron Web site (www.extron.com). Installing the Software The control program is contained on the included disk.
Contact Closure Remote Control For contact closure, connect a contact closure remote control device to the contact closure female 5-pole captive screw connector of the front panel. Various AAP devices and cable assemblies are also available from Extron to provide remote contact closure capability. The pin assignments for the contact closure connector of the RGB 580xi are shown in the following table.
Specifications, Part Numbers, and Accessories This section discusses the specifications, part numbers, and accessories for the RGB 580xi. Topics that are covered, include: • Specifications • Part Numbers and Accessories Specifications Video — RGB 580xi Gain ����������������������������������������������� 0.35 V to 1.
Sync Input type �������������������������������������� Output type ����������������������������������� Input level �������������������������������������� Output level ����������������������������������� Input impedance ���������������������������� Output impedance ������������������������� Max. propagation delay ������������������ Max. rise/fall time ��������������������������� Polarity RGBHV ������������������������������������ RGBHV, RGBS, RGsB, RsGsBs RGBHV, RGBS, RGsB 2 V to 5.5 Vp-p with ±0.
Enclosure dimensions RGB 580xi ������������������������������� 1.75" H x 6.4" W x 6.0" D 4.4 cm H x 16.3 cm W x 15.2 cm D (Depth excludes connectors.) RGB 580xi AAP models Faceplate ��������������������������� 1.4" H x 3.5" W x 0.1" D (3.6 cm H x 8.9 cm W x 0.3 cm D) (double-space high AAP plates) Circuit board ���������������������� 1.3" H x 2.5" W x 0.9" D (3.3 cm H x 6.4 cm W x 2.3 cm D) (Depth excludes connectors, knobs, and faceplate.) Product weight RGB 580xi I AAP 3', RGB 580xi SI AAP 3' 0.4 lbs (0.
Part Numbers and Accessories Included Parts Included parts Replacement part number RGB 580xi 60-362-01 3.5 mm, 5-pole captive screw connectors (10) 100-460-01 3.5 mm, 3-pole captive screw connectors (10) 100-459-01 MBU 125 under-desk mount kit 70-077-01 RGB 580xi setup guide IEC power cord Windows -based control software Optional AAP Cables Accessories Part number RGB 580xi AAP 3' (0.9 m) (black, white) 70-128-02, -03 RGB 580xi AAP 6' (1.
Mounting This section discusses how to connect and configure the RGB 580xi. Topics that are covered, include: • Under-furniture Mounting • Mounting the Optional AAP Device • Mounting Template Under-furniture Mounting 1. Attach the under-desk mounting brackets (part #70-077-01) to the interface with the four machine screws (provided in the mounting kit), as shown below. This procedure may also apply to table or podium mounting applications. See “Application Diagrams”. 2.
Mounting the Optional AAP Device Various Extron RGB 580xi AAP double-space devices may be mounted to any Extron product that has an AAP faceplate, or to an Extron AAP wallplate. The AAP device should be cabled before it is attached to a faceplate or wallplate (see “Cabling the AAP Device Rear Connectors”). The screws needed for installing an AAP device are built into its front panel, so no additional screws are needed. 1.
Mounting Template Dimensions For under-desk mounting, use the bracket mounting kit that is included with the RGB 580xi, and see the template diagram below. NOTE: These cables apply only to the RGB 580xi AAP, RGB 580xi S AAP, and RGB 580xi SI AAP; they do not apply to the RGB 580xi CCS AAP or RGB 580xi CCSI AAP. 6.95 6.35 0.6 1.79” x 6.35” OPENING IN DESK Recommended pilot drill hole size for supplied screws = 3/32” x 1/4” deep.
Extron® Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase.
Extron USA - West Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 Inside USA/Canada Only +800.633.9876 Inside USA/Canada Only +800.3987.6673 Inside Europe Only +800.7339.8766 Inside Asia Only +81.3.3511.7655 +81.3.3511.7656 FAX +400.833.1568 Inside China Only +971.4.2991800 +971.4.2991880 FAX +1.714.491.1500 +1.714.491.1517 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.